Schneider Electric BDL36040 Molded Case Circuit Brkr 600Y/347V 40A

(No reviews yet) Write a Review
SKU:
BDL36040
UPC:
3606481153074
Condition:
New
Mechanical Durability:
20000 cycles IEC 947-1 Annex K ed 5.2
Color:
Gray RAL 7016)
Product Or Component Type:
circuit breaker
Ip Degree Of Protection:
front cover IP40 IEC 60529
Utilisation Category:
category A
Suitability For Isolation:
yes IEC 60947-2
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Breaking Capacity:
25 kA 208Y/120 V AC 50/60 Hz UL 489 || 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480/277 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz UL 489 || 14 kA 600Y/347 V AC 50/60 Hz UL 489 || 10 kA 250 V DC UL 489
Line Rated Current:
40-40 A
Ambient Air Temperature For Storage:
-50-85 °C
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Device Short Name:
BD 040
Range:
PowerPact
Standards:
NEMA AB1 || EN/IEC 60947-2 || GB 14048.2 || NMX J-266 || CSA C22.2 No 5 || UL 489 || EN/IEC 60947-5-1
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Width:
81 mm
Connection Pitch:
27 mm
Mounting Mode:
clip-on 35 x 15 mm symmetrical DIN rail) || by screws plate)
Ik Degree Of Protection:
IK07 IEC 62262
Quantity Per Set:
set of 1
Control Type:
toggle
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
Number Of Slots:
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in) || 1 alarm switch SD plug-in)
Net Weight:
1.074 kg
Device Application:
distribution
Electrical Connection:
Everlink lug, line || Everlink lug, load
Height:
137 mm
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Circuit Breaker Application:
HACR rated
9 Mm Pitches:
9
Pollution Degree:
3 IEC 60947-1
Quality Labels:
CE
Sustainable Offer Status:
Green Premium product
[Ics] Rated Service Breaking Capacity:
25 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 14 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 18 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 18 kA 440 V AC 50/60 Hz IEC 60947-2
Continuous Current Rating:
0.8
Breaking Capacity Code:
D
Circularity Profile:
N/A
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Wire Stripping Length:
20 mm
Network Frequency:
50/60 Hz
Environmental Disclosure:
ENVPEP1610005EN
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Tightening Torque:
5-5 N.m 2.5-16 mm² (AWG 14...AWG 4) || 9-9 N.m 25-95 mm² (AWG 3...AWG 3/0)
Depth:
80 mm
Product Name:
PowerPact B
[Ue] Rated Operational Voltage:
525 V AC 50/60 Hz UL 489
Eu Rohs Directive:
Compliant with Exemptions
Pvc Free:
Yes
Mercury Free:
Yes
Halogen Content Performance:
Halogen free product
Awg Gauge:
AWG 6...AWG 2/0 fine stranded aluminium/copper || AWG 14...AWG 3/0 rigid or stranded aluminium/copper
Trip Unit Technology:
thermal-magnetic
Local Signalling:
presence of auxiliary contacts flag green)
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
Poles Description:
3P
Rohs Exemption Information:
Yes
Ambient Air Temperature For Operation:
-25-70 °C
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric BDL36040 Molded Case Circuit Brkr 600Y/347V 40A
  • Schneider Electric BDL36040 Molded Case Circuit Brkr 600Y/347V 40A
  • Schneider Electric BDL36040 Molded Case Circuit Brkr 600Y/347V 40A
$979.00

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. This circuit breaker's unit mount construction features traditional back pan mounting with screws or integrated DIN rail mounting for installation flexibility. This unit features EverLink lugs, a patented design to reduce loosening of cables over time, on both termination ends. This PowerPacT B, 40A, 3 pole, circuit breaker has a breaking capacity of 14kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose