Electrical Connection:
Everlink lug, line || Everlink lug, load
Ik Degree Of Protection:
IK07 IEC 62262
Depth:
80 mm
Awg Gauge:
AWG 6...AWG 2/0 fine stranded aluminium/copper || AWG 14...AWG 3/0 rigid or stranded aluminium/copper
Continuous Current Rating:
0.8
Device Short Name:
BD 070
Utilisation Category:
category A
Circularity Profile:
N/A
Width:
54 mm
Halogen Content Performance:
Halogen free product
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Pvc Free:
Yes
Trip Unit Technology:
thermal-magnetic
Tightening Torque:
5-5 N.m 2.5-16 mm² (AWG 14...AWG 4) || 9-9 N.m 25-95 mm² (AWG 3...AWG 3/0)
Network Frequency:
50/60 Hz
[Ue] Rated Operational Voltage:
525 V AC 50/60 Hz UL 489
Product Or Component Type:
circuit breaker
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Breaking Capacity:
25 kA 208Y/120 V AC 50/60 Hz UL 489 || 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480/277 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz UL 489 || 14 kA 600Y/347 V AC 50/60 Hz UL 489 || 10 kA 250 V DC UL 489
Product Name:
PowerPact B
Eu Rohs Directive:
Compliant with Exemptions
Pollution Degree:
3 IEC 60947-1
Ambient Air Temperature For Operation:
-25-70 °C
Rohs Exemption Information:
Yes
Local Signalling:
presence of auxiliary contacts flag green)
Net Weight:
0.769 kg
Standards:
NEMA AB1 || CSA C22.2 No 5 || EN/IEC 60947-5-1 || NMX J-266 || UL 489 || GB 14048.2 || EN/IEC 60947-2
Accessory / Separate Part Type:
control wire
Mercury Free:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
Circuit Breaker Application:
HACR rated
Quality Labels:
CE
Breaking Capacity Code:
D
Quantity Per Set:
set of 1
Device Application:
distribution
Sustainable Offer Status:
Green Premium product
Line Rated Current:
70-70 A
[Ics] Rated Service Breaking Capacity:
14 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 18 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 25 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 18 kA 440 V AC 50/60 Hz IEC 60947-2
Height:
137 mm
Control Type:
toggle
Ambient Air Temperature For Storage:
-50-85 °C
Poles Description:
3P
Ip Degree Of Protection:
front cover IP40 IEC 60529
9 Mm Pitches:
6
Mounting Mode:
clip-on 35 x 15 mm symmetrical DIN rail) || by screws plate)
Range:
PowerPact
Wire Stripping Length:
20 mm
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Environmental Disclosure:
ENVPEP1610005EN
Color:
Gray RAL 7016)
Suitability For Isolation:
yes IEC 60947-2
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Mechanical Durability:
20000 cycles IEC 947-1 Annex K ed 5.2
Number Of Slots:
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in)
Connection Pitch:
27 mm
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric BDL36070LV Molded Case Circuit Breaker 480V 70A
  • Schneider Electric BDL36070LV Molded Case Circuit Breaker 480V 70A
  • Schneider Electric BDL36070LV Molded Case Circuit Breaker 480V 70A
$1,306.00

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. This circuit breaker's unit mount construction features traditional back pan mounting with screws or integrated DIN rail mounting for installation flexibility. This unit features EverLink lugs, a patented design to reduce loosening of cables over time, on both termination ends. This PowerPacT B, 70A, 3 pole, circuit breaker has a breaking capacity of 14kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80%. This unit includes a control wire terminal on the load end EverLink lug. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.