Schneider Electric BDL36110 Molded Case Circuit Brkr 600Y/347V 110A

(No reviews yet) Write a Review
SKU:
BDL36110
UPC:
3606489779191
Condition:
New
Sustainable Offer Status:
Green Premium product
Ambient Air Temperature For Storage:
-50-85 °C
Control Type:
toggle
Pollution Degree:
3 IEC 60947-1
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
Standards:
NEMA AB1 || CSA C22.2 No 5 || UL 489 || EN/IEC 60947-5-1 || NMX J-266 || EN/IEC 60947-2 || GB 14048.2
Halogen Content Performance:
Halogen free product
Device Short Name:
BD 110
Eu Rohs Directive:
Compliant with Exemptions
Ip Degree Of Protection:
front cover IP40 IEC 60529
Mechanical Durability:
20000 cycles IEC 947-1 Annex K ed 5.2
Product Name:
PowerPact B
Net Weight:
1.074 kg
Product Or Component Type:
circuit breaker
Environmental Disclosure:
ENVPEP1610005EN
[Ics] Rated Service Breaking Capacity:
25 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 14 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 18 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 18 kA 440 V AC 50/60 Hz IEC 60947-2
Continuous Current Rating:
0.8
Mercury Free:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Color:
Gray RAL 7016)
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Quality Labels:
CE
Range:
PowerPact
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Breaking Capacity:
25 kA 208Y/120 V AC 50/60 Hz UL 489 || 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480/277 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz UL 489 || 14 kA 600Y/347 V AC 50/60 Hz UL 489 || 10 kA 250 V DC UL 489
Breaking Capacity Code:
D
Network Frequency:
50/60 Hz
Utilisation Category:
category A
Local Signalling:
presence of auxiliary contacts flag green)
Line Rated Current:
110-110 A
Trip Unit Technology:
thermal-magnetic
Connection Pitch:
27 mm
Poles Description:
3P
Circularity Profile:
N/A
Pvc Free:
Yes
Depth:
80 mm
Device Application:
distribution
Suitability For Isolation:
yes IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Height:
137 mm
Ik Degree Of Protection:
IK07 IEC 62262
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Tightening Torque:
5-5 N.m 2.5-16 mm² (AWG 14...AWG 4) || 9-9 N.m 25-95 mm² (AWG 3...AWG 3/0)
Wire Stripping Length:
20 mm
9 Mm Pitches:
9
Awg Gauge:
AWG 6...AWG 2/0 fine stranded aluminium/copper || AWG 14...AWG 3/0 rigid or stranded aluminium/copper
Width:
81 mm
Electrical Connection:
Everlink lug, line || Everlink lug, load
Ambient Air Temperature For Operation:
-25-70 °C
Mounting Mode:
clip-on 35 x 15 mm symmetrical DIN rail) || by screws plate)
Circuit Breaker Application:
HACR rated
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Quantity Per Set:
set of 1
Rohs Exemption Information:
Yes
Number Of Slots:
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in) || 1 alarm switch SD plug-in)
[Ue] Rated Operational Voltage:
525 V AC 50/60 Hz UL 489
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric BDL36110 Molded Case Circuit Brkr 600Y/347V 110A
  • Schneider Electric BDL36110 Molded Case Circuit Brkr 600Y/347V 110A
  • Schneider Electric BDL36110 Molded Case Circuit Brkr 600Y/347V 110A
$1,494.00

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. This circuit breaker's unit mount construction features traditional back pan mounting with screws or integrated DIN rail mounting for installation flexibility. This unit features EverLink lugs, a patented design to reduce loosening of cables over time, on both termination ends. This PowerPacT B, 110A, 3 pole, circuit breaker has a breaking capacity of 14kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose