Schneider Electric BGA160151 Molded Case Circuit Breaker 347V 15A
Schneider Electric
$517.00
PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. I-Line circuit breakers come with a shrouded I-Line plug on jaw. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT B, 15A, 1 pole, circuit breaker has a breaking capacity of 18kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80% with an A phase connection. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Ambient Air Temperature For Operation:
- -25-70 °C
- Standards:
- GB 14048.2 || UL 489 || EN/IEC 60947-2 || NEMA AB1 || NMX J-266 || CSA C22.2 No 5 || EN/IEC 60947-5-1
- Circularity Profile:
- N/A
- Height:
- 137 mm
- Control Type:
- toggle
- Product Certifications:
- UL || IEC || CCC || EAC || CSA || NOM
- Breaking Capacity:
- 65 kA 208Y/120 V AC 50/60 Hz UL 489 || 65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480Y/277 V AC 50/60 Hz UL 489 || 18 kA 600Y/347 V AC 50/60 Hz UL 489 || 20 kA 125 V DC UL 489
- Net Weight:
- 0.6375 kg
- Network Frequency:
- 50/60 Hz
- 9 Mm Pitches:
- 3
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Eu Rohs Directive:
- Compliant with Exemptions
- Environmental Disclosure:
- ENVPEP1610005EN
- Mounting Mode:
- I-Line
- Mechanical Durability:
- 20000 cycles IEC 947-1 Annex K ed 5.2
- Electrical Connection:
- I-Line connection, line || lugs, load
- Pvc Free:
- Yes
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Poles Description:
- 1P
- Quality Labels:
- CE
- Quantity Per Set:
- set of 1
- Color:
- Gray RAL 7016)
- Device Application:
- distribution
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- [Ui] Rated Insulation Voltage:
- 800 V IEC 60947-2
- Width:
- 27 mm
- [Ue] Rated Operational Voltage:
- 240 V AC 50/60 Hz UL 489
- Connection Pitch:
- 27 mm
- Local Signalling:
- presence of auxiliary contacts flag green)
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Depth:
- 89 mm
- Product Or Component Type:
- circuit breaker
- Mounting Height:
- 38.1 mm
- Continuous Current Rating:
- 0.8
- Product Name:
- PowerPact B
- Circuit Breaker Application:
- HACR rated
- Pollution Degree:
- 3 IEC 60947-1
- Breaking Capacity Code:
- G
- Awg Gauge:
- AWG 14...AWG 2/0 aluminium/copper
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Trip Unit Technology:
- thermal-magnetic
- Phase Connection:
- A
- Rohs Exemption Information:
- Yes
- Ik Degree Of Protection:
- IK07 IEC 62262
- Utilisation Category:
- category A
- Wire Stripping Length:
- 20 mm
- Sustainable Offer Status:
- Green Premium product
- Range:
- PowerPact
- Device Short Name:
- BG 015
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Suitability For Isolation:
- yes IEC 60947-2
- [Ics] Rated Service Breaking Capacity:
- 65 kA 220...240 V AC 50/60 Hz IEC 60947-2
- Halogen Content Performance:
- Halogen free product
- Mercury Free:
- Yes
- Line Rated Current:
- 15-15 A
- Electrical Durability:
- 10000 cycles IEC 947-1 Annex K ed 5.2 240 V In
- Tightening Torque:
- 3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
- Ambient Air Temperature For Storage:
- -50-85 °C
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View