Schneider Electric BGA160301 Molded Case Circuit Breaker 347V 30A

(No reviews yet) Write a Review
SKU:
BGA160301
UPC:
3606481153371
Condition:
New
[Ics] Rated Service Breaking Capacity:
65 kA 220...240 V AC 50/60 Hz IEC 60947-2
Pollution Degree:
3 IEC 60947-1
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Mounting Height:
38.1 mm
Pvc Free:
Yes
Poles Description:
1P
Depth:
89 mm
Continuous Current Rating:
0.8
Local Signalling:
presence of auxiliary contacts flag green)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Device Short Name:
BG 030
Sustainable Offer Status:
Green Premium product
Line Rated Current:
30-30 A
Mercury Free:
Yes
Standards:
UL 489 || NMX J-266 || EN/IEC 60947-5-1 || NEMA AB1 || EN/IEC 60947-2 || CSA C22.2 No 5 || GB 14048.2
Environmental Disclosure:
ENVPEP1610005EN
Device Application:
distribution
Mounting Mode:
I-Line
Net Weight:
0.6375 kg
Electrical Connection:
I-Line connection, line || lugs, load
Circularity Profile:
N/A
Eu Rohs Directive:
Compliant with Exemptions
Product Name:
PowerPact B
Breaking Capacity Code:
G
9 Mm Pitches:
3
Awg Gauge:
AWG 14...AWG 2/0 aluminium/copper
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Control Type:
toggle
Quantity Per Set:
set of 1
Quality Labels:
CE
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 240 V In
Height:
137 mm
Phase Connection:
A
Suitability For Isolation:
yes IEC 60947-2
Breaking Capacity:
65 kA 208Y/120 V AC 50/60 Hz UL 489 || 65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480Y/277 V AC 50/60 Hz UL 489 || 18 kA 600Y/347 V AC 50/60 Hz UL 489 || 20 kA 125 V DC UL 489
[Ue] Rated Operational Voltage:
240 V AC 50/60 Hz UL 489
Range:
PowerPact
Network Frequency:
50/60 Hz
Tightening Torque:
3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
Mechanical Durability:
20000 cycles IEC 947-1 Annex K ed 5.2
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Rohs Exemption Information:
Yes
Wire Stripping Length:
20 mm
Connection Pitch:
27 mm
Trip Unit Technology:
thermal-magnetic
Ik Degree Of Protection:
IK07 IEC 62262
Halogen Content Performance:
Halogen free product
Circuit Breaker Application:
HACR rated
Utilisation Category:
category A
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
Ambient Air Temperature For Operation:
-25-70 °C
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Product Or Component Type:
circuit breaker
Ip Degree Of Protection:
front cover IP40 IEC 60529
Width:
27 mm
Color:
Gray RAL 7016)
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Ambient Air Temperature For Storage:
-50-85 °C
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric BGA160301 Molded Case Circuit Breaker 347V 30A
  • Schneider Electric BGA160301 Molded Case Circuit Breaker 347V 30A
  • Schneider Electric BGA160301 Molded Case Circuit Breaker 347V 30A
$517.00

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. I-Line circuit breakers come with a shrouded I-Line plug on jaw. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT B, 30A, 1 pole, circuit breaker has a breaking capacity of 18kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80% with an A phase connection. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose