Electrical Connection:
I-Line connection, line || lugs, load
Pollution Degree:
3 IEC 60947-1
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
Rohs Exemption Information:
Yes
Awg Gauge:
AWG 14...AWG 2/0 aluminium/copper
Device Application:
distribution
Breaking Capacity Code:
G
[Ics] Rated Service Breaking Capacity:
65 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 18 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 35 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 35 kA 440 V AC 50/60 Hz IEC 60947-2
Mercury Free:
Yes
Mounting Height:
76.2 mm
Circularity Profile:
N/A
Connection Pitch:
27 mm
Tightening Torque:
3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
Ik Degree Of Protection:
IK07 IEC 62262
Height:
137 mm
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
Quality Labels:
CE
Net Weight:
0.952 kg
Eu Rohs Directive:
Compliant with Exemptions
Number Of Slots:
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in)
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Suitability For Isolation:
yes IEC 60947-2
Breaking Capacity:
65 kA 208Y/120 V AC 50/60 Hz UL 489 || 65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480/277 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 18 kA 600Y/347 V AC 50/60 Hz UL 489
Mechanical Durability:
20000 cycles IEC 947-1 Annex K ed 5.2
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Phase Connection:
AC
Product Or Component Type:
circuit breaker
Network Frequency:
50/60 Hz
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Color:
Gray RAL 7016)
Pvc Free:
Yes
Sustainable Offer Status:
Green Premium product
Product Name:
PowerPact B
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Device Short Name:
BG 100
Local Signalling:
presence of auxiliary contacts flag green)
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Range:
PowerPact
Ambient Air Temperature For Operation:
-25-70 °C
Continuous Current Rating:
0.8
[Ue] Rated Operational Voltage:
525 V AC 50/60 Hz UL 489
Standards:
EN/IEC 60947-5-1 || CSA C22.2 No 5 || GB 14048.2 || EN/IEC 60947-2 || UL 489 || NMX J-266 || NEMA AB1
Quantity Per Set:
set of 1
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Wire Stripping Length:
20 mm
Poles Description:
2P
Line Rated Current:
100-100 A
Trip Unit Technology:
thermal-magnetic
Utilisation Category:
category A
Control Type:
toggle
Depth:
89 mm
Mounting Mode:
I-Line
Ambient Air Temperature For Storage:
-50-85 °C
9 Mm Pitches:
6
Halogen Content Performance:
Halogen free product
Environmental Disclosure:
ENVPEP1610005EN
Ip Degree Of Protection:
front cover IP40 IEC 60529
Width:
54 mm
Circuit Breaker Application:
HACR rated
  • Schneider Electric BGA24100Y2 Molded Case Circuit Brkr 480Y/277V 100A
  • Schneider Electric BGA24100Y2 Molded Case Circuit Brkr 480Y/277V 100A
  • Schneider Electric BGA24100Y2 Molded Case Circuit Brkr 480Y/277V 100A
$1,129.00

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 35kA at 480Y/277VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. I-Line circuit breakers come with a shrouded I-Line plug on jaw. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT B, 100A, 2 pole, circuit breaker has a breaking capacity of 35kA at 480Y/277VAC. This circuit breaker has a continuous current rating of 80% with an AC phase connection. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose