Schneider Electric BGF36040 Molded Case Circuit Brkr 600Y/347V 40A

(No reviews yet) Write a Review
SKU:
BGF36040
UPC:
3606481149558
Condition:
New
Suitability For Isolation:
yes IEC 60947-2
Mounting Mode:
clip-on 35 mm symmetrical DIN rail) || by screws plate)
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Local Signalling:
presence of auxiliary contacts flag green)
[Ue] Rated Operational Voltage:
525 V AC 50/60 Hz UL 489
Ip Degree Of Protection:
front cover IP40 IEC 60529
Wire Stripping Length:
20 mm
Width:
81 mm
Product Or Component Type:
circuit breaker
Network Frequency:
50/60 Hz
Tightening Torque:
5-5 N.m 2.5-16 mm² (AWG 14...AWG 4) || 9-9 N.m 25-95 mm² (AWG 3...AWG 3/0)
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Connection Pitch:
27 mm
Poles Description:
3P
Breaking Capacity:
65 kA 208Y/120 V AC 50/60 Hz UL 489 || 65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480/277 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 18 kA 600Y/347 V AC 50/60 Hz UL 489
Standards:
EN/IEC 60947-2 || NEMA AB1 || GB 14048.2 || NMX J-266 || CSA C22.2 No 5 || UL 489 || EN/IEC 60947-5-1
Sustainable Offer Status:
Green Premium product
Circularity Profile:
N/A
Halogen Content Performance:
Halogen free product
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
Operating Altitude:
6561.68 ft (2000 m) without derating || 5000 m with derating
Quantity Per Set:
set of 1
Net Weight:
0.924 kg
Number Of Slots:
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in) || 1 alarm switch SD plug-in)
Height:
137 mm
Circuit Breaker Application:
HACR rated
Color:
Gray RAL 7016)
Eu Rohs Directive:
Compliant with Exemptions
[Ics] Rated Service Breaking Capacity:
65 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 18 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 35 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 35 kA 440 V AC 50/60 Hz IEC 60947-2
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
9 Mm Pitches:
9
Ambient Air Temperature For Storage:
-50-85 °C
Control Type:
toggle
Trip Unit Name:
TM-D
Product Name:
PowerPact B
Range:
PowerPact
Ik Degree Of Protection:
IK07 IEC 62262
Ambient Air Temperature For Operation:
-25-70 °C
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Environmental Disclosure:
ENVPEP1610005EN
Device Application:
distribution
Device Short Name:
BG 040
Quality Labels:
CE
Awg Gauge:
AWG 14...AWG 8 aluminium/copper || AWG 6...AWG 3/0 aluminium/copper
Rohs Exemption Information:
Yes
Pvc Free:
Yes
Depth:
80 mm
Protected Poles Description:
3t
Continuous Current Rating:
0.8
Breaking Capacity Code:
G
Pollution Degree:
3 IEC 60947-1
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Mechanical Durability:
15000 cycles IEC 947-1 Annex K ed 5.2
Trip Unit Technology:
thermal-magneticTM-D,
Utilisation Category:
category A
Electrical Connection:
terminal nut, ON and OFF end
Line Rated Current:
40-40 A
Mercury Free:
Yes
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric BGF36040 Molded Case Circuit Brkr 600Y/347V 40A
  • Schneider Electric BGF36040 Molded Case Circuit Brkr 600Y/347V 40A
  • Schneider Electric BGF36040 Molded Case Circuit Brkr 600Y/347V 40A
$1,344.00

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. This circuit breaker's unit mount construction features traditional back pan mounting with screws or integrated DIN rail mounting for installation flexibility. This unit has terminal nuts on both termination ends. This PowerPacT B, 40A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked. EverLink lugs are also available with unique integrated control wire terminals.
View AllClose