Schneider Electric BGL36100LU Molded Case Circuit Brkr 600Y/347V 100A

(No reviews yet) Write a Review
SKU:
BGL36100LU
UPC:
3606481149473
Condition:
New
Number Of Slots:
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in) || 1 alarm switch SD plug-in)
[Ics] Rated Service Breaking Capacity:
65 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 18 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 35 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 35 kA 440 V AC 50/60 Hz IEC 60947-2
Ip Degree Of Protection:
front cover IP40 IEC 60529
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Net Weight:
1.074 kg
Ik Degree Of Protection:
IK07 IEC 62262
Line Rated Current:
100-100 A
Ambient Air Temperature For Operation:
-25-70 °C
Device Short Name:
BG 100
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Mercury Free:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Mechanical Durability:
15000 cycles IEC 947-1 Annex K ed 5.2
9 Mm Pitches:
9
Local Signalling:
presence of auxiliary contacts flag green)
Breaking Capacity:
65 kA 208Y/120 V AC 50/60 Hz UL 489 || 65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480/277 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 18 kA 600Y/347 V AC 50/60 Hz UL 489
Quality Labels:
CE
Standards:
NEMA AB1 || NMX J-266 || EN/IEC 60947-2 || EN/IEC 60947-5-1 || GB 14048.2 || CSA C22.2 No 5 || UL 489
Control Type:
toggle
Halogen Content Performance:
Halogen free product
Connection Pitch:
27 mm
Operating Altitude:
6561.68 ft (2000 m) without derating || 5000 m with derating
Ambient Air Temperature For Storage:
-50-85 °C
Tightening Torque:
5-5 N.m 2.5-16 mm² (AWG 14...AWG 4) || 9-9 N.m 25-95 mm² (AWG 3...AWG 3/0)
Environmental Disclosure:
ENVPEP1610005EN
Range:
PowerPact
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Pvc Free:
Yes
Width:
81 mm
[Ue] Rated Operational Voltage:
525 V AC 50/60 Hz UL 489
Breaking Capacity Code:
G
Device Application:
distribution
Network Frequency:
50/60 Hz
Eu Rohs Directive:
Compliant with Exemptions
Product Name:
PowerPact B
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Pollution Degree:
3 IEC 60947-1
Quantity Per Set:
set of 1
Sustainable Offer Status:
Green Premium product
Trip Unit Technology:
thermal-magneticTM-D,
Electrical Connection:
Everlink lug, line || Everlink lug, load
Poles Description:
3P
Height:
137 mm
Circularity Profile:
N/A
Awg Gauge:
AWG 6...AWG 2/0 fine stranded aluminium/copper || AWG 14...AWG 3/0 rigid or stranded aluminium/copper
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
Circuit Breaker Application:
HACR rated
Depth:
80 mm
Product Or Component Type:
circuit breaker
Mounting Mode:
clip-on 35 mm symmetrical DIN rail) || by screws plate)
Color:
Gray RAL 7016)
Protected Poles Description:
3t
Rohs Exemption Information:
Yes
Wire Stripping Length:
20 mm
Suitability For Isolation:
yes IEC 60947-2
Trip Unit Name:
TM-D
Continuous Current Rating:
0.8
Utilisation Category:
category A
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric BGL36100LU Molded Case Circuit Brkr 600Y/347V 100A
  • Schneider Electric BGL36100LU Molded Case Circuit Brkr 600Y/347V 100A
  • Schneider Electric BGL36100LU Molded Case Circuit Brkr 600Y/347V 100A
$1,642.00

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. This circuit breaker's unit mount construction features traditional back pan mounting with screws or integrated DIN rail mounting for installation flexibility. This unit features EverLink lugs, a patented design to reduce loosening of cables over time, on both termination ends. This PowerPacT B, 100A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80%. This unit includes a control wire terminal on the line end EverLink lug. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked. EverLink lugs are also available with unique integrated control wire terminals.