Schneider Electric BJA260151 Molded Case Circuit Brkr 600Y/347V 15A

(No reviews yet) Write a Review
SKU:
BJA260151
UPC:
3606481154194
Condition:
New
Device Short Name:
BJ 015
9 Mm Pitches:
6
Height:
137 mm
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
Range:
PowerPact
Color:
Gray RAL 7016)
Mercury Free:
Yes
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
Number Of Slots:
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in)
Breaking Capacity:
100 kA 208Y/120 V AC 50/60 Hz UL 489 || 100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480/277 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600Y/347 V AC 50/60 Hz UL 489 || 50 kA 250 V DC UL 489
Depth:
89 mm
Quantity Per Set:
set of 1
Local Signalling:
presence of auxiliary contacts flag green)
Ambient Air Temperature For Storage:
-50-85 °C
Rohs Exemption Information:
Yes
Phase Connection:
AB
Continuous Current Rating:
0.8
Eu Rohs Directive:
Compliant with Exemptions
Control Type:
toggle
Line Rated Current:
15-15 A
[Ics] Rated Service Breaking Capacity:
100 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 25 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 10 kA 690 V AC 50/60 Hz IEC 60947-2 || 65 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 65 kA 440 V AC 50/60 Hz IEC 60947-2
Pvc Free:
Yes
Width:
54 mm
Pollution Degree:
3 IEC 60947-1
Circuit Breaker Application:
HACR rated
Network Frequency:
50/60 Hz
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz UL 489
Ambient Air Temperature For Operation:
-25-70 °C
Poles Description:
2P
Mechanical Durability:
20000 cycles IEC 947-1 Annex K ed 5.2
Tightening Torque:
3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Mounting Height:
76.2 mm
Environmental Disclosure:
ENVPEP1610005EN
Net Weight:
0.952 kg
Sustainable Offer Status:
Green Premium product
Halogen Content Performance:
Halogen free product
Ip Degree Of Protection:
front cover IP40 IEC 60529
Circularity Profile:
N/A
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Trip Unit Technology:
thermal-magnetic
Mounting Mode:
I-Line
Breaking Capacity Code:
J
Device Application:
distribution
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Standards:
CSA C22.2 No 5 || EN/IEC 60947-2 || EN/IEC 60947-5-1 || NEMA AB1 || UL 489 || GB 14048.2 || NMX J-266
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Ik Degree Of Protection:
IK07 IEC 62262
Quality Labels:
CE
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Awg Gauge:
AWG 14...AWG 2/0 aluminium/copper
Electrical Connection:
I-Line connection, line || lugs, load
Product Name:
PowerPact B
Connection Pitch:
27 mm
Utilisation Category:
category A
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Suitability For Isolation:
yes IEC 60947-2
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Wire Stripping Length:
20 mm
Product Or Component Type:
circuit breaker
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric BJA260151 Molded Case Circuit Brkr 600Y/347V 15A
  • Schneider Electric BJA260151 Molded Case Circuit Brkr 600Y/347V 15A
  • Schneider Electric BJA260151 Molded Case Circuit Brkr 600Y/347V 15A
$1,541.00

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 25kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. I-Line circuit breakers come with a shrouded I-Line plug on jaw. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT B, 15A, 2 pole, circuit breaker has a breaking capacity of 25kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80% with an AB phase connection. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose