Schneider Electric BJA36060 Molded Case Circuit Brkr 600Y/347V 60A
Schneider Electric
$1,928.00
PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 25kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. I-Line circuit breakers come with a shrouded I-Line plug on jaw. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT B, 60A, 3 pole, circuit breaker has a breaking capacity of 25kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Control Type:
- toggle
- Color:
- Gray RAL 7016)
- Pvc Free:
- Yes
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Mounting Height:
- 114 mm
- Utilisation Category:
- category A
- Device Short Name:
- BJ 060
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Sustainable Offer Status:
- Green Premium product
- Ik Degree Of Protection:
- IK07 IEC 62262
- [Ics] Rated Service Breaking Capacity:
- 100 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 25 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 10 kA 690 V AC 50/60 Hz IEC 60947-2 || 65 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 65 kA 440 V AC 50/60 Hz IEC 60947-2
- 9 Mm Pitches:
- 9
- Product Name:
- PowerPact B
- Mercury Free:
- Yes
- Poles Description:
- 3P
- Halogen Content Performance:
- Halogen free product
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Continuous Current Rating:
- 0.8
- Product Certifications:
- UL || IEC || CCC || EAC || CSA || NOM
- Eu Rohs Directive:
- Compliant with Exemptions
- Awg Gauge:
- AWG 14...AWG 2/0 aluminium/copper
- Ambient Air Temperature For Storage:
- -50-85 °C
- Ambient Air Temperature For Operation:
- -25-70 °C
- Local Signalling:
- presence of auxiliary contacts flag green)
- Connection Pitch:
- 27 mm
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Wire Stripping Length:
- 20 mm
- Suitability For Isolation:
- yes IEC 60947-2
- Rohs Exemption Information:
- Yes
- Breaking Capacity Code:
- J
- Electrical Durability:
- 10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
- Circuit Breaker Application:
- HACR rated
- Tightening Torque:
- 3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
- Device Application:
- distribution
- Phase Connection:
- ABC
- Range:
- PowerPact
- Network Frequency:
- 50/60 Hz
- Trip Unit Technology:
- thermal-magnetic
- Environmental Disclosure:
- ENVPEP1610005EN
- Circularity Profile:
- N/A
- Quality Labels:
- CE
- Breaking Capacity:
- 100 kA 208Y/120 V AC 50/60 Hz UL 489 || 100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480/277 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600Y/347 V AC 50/60 Hz UL 489 || 50 kA 250 V DC UL 489
- Line Rated Current:
- 60-60 A
- Depth:
- 89 mm
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Number Of Slots:
- 1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in) || 1 alarm switch SD plug-in)
- Width:
- 81 mm
- [Ui] Rated Insulation Voltage:
- 800 V IEC 60947-2
- Mounting Mode:
- I-Line
- Mechanical Durability:
- 20000 cycles IEC 947-1 Annex K ed 5.2
- Product Or Component Type:
- circuit breaker
- Standards:
- UL 489 || GB 14048.2 || CSA C22.2 No 5 || NEMA AB1 || EN/IEC 60947-2 || EN/IEC 60947-5-1 || NMX J-266
- Pollution Degree:
- 3 IEC 60947-1
- Net Weight:
- 1.315 kg
- Electrical Connection:
- I-Line connection, line || lugs, load
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Height:
- 137 mm
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz UL 489
- Quantity Per Set:
- set of 1
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View