Schneider Electric BJF46100 Molded Case Circuit Brkr 600Y/347V 100A

Schneider Electric
SKU:
BJF46100
|
UPC:
3606481150820
Availability:
Factory stock
$3,037.00
Condition:
New
$1200 Minimum Order for Non-stock Items or $60 Addl Schneider Handling Fee Applies
Current Stock:
Circuit breaker, PowerPacT B, 100A, 4 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%
Depth:
80 mm
Range:
PowerPact
Quantity Per Set:
set of 1
Circularity Profile:
N/A
Protected Poles Description:
4t
Quality Labels:
CE
Tightening Torque:
5-5 N.m 2.5-16 mm² (AWG 14...AWG 4) || 9-9 N.m 25-95 mm² (AWG 3...AWG 3/0)
Product Or Component Type:
circuit breaker
Ambient Air Temperature For Operation:
-25-70 °C
Breaking Capacity Code:
J
Mercury Free:
Yes
Ip Degree Of Protection:
front cover IP40 IEC 60529
Poles Description:
4P
Utilisation Category:
category A
Continuous Current Rating:
0.8
[Ics] Rated Service Breaking Capacity:
100 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 25 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 2.5 kA 690 V AC 50/60 Hz IEC 60947-2 || 65 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 65 kA 440 V AC 50/60 Hz IEC 60947-2
Trip Unit Technology:
thermal-magneticTM-D,
Mounting Mode:
clip-on 35 mm symmetrical DIN rail) || by screws plate)
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Ambient Air Temperature For Storage:
-50-85 °C
Awg Gauge:
AWG 14...AWG 8 aluminium/copper || AWG 6...AWG 3/0 aluminium/copper
Pvc Free:
Yes
Wire Stripping Length:
20 mm
Operating Altitude:
6561.68 ft (2000 m) without derating || 5000 m with derating
Pollution Degree:
3 IEC 60947-1
Halogen Content Performance:
Halogen free product
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
Ik Degree Of Protection:
IK07 IEC 62262
Net Weight:
1.241 kg
Device Application:
distribution
Mechanical Durability:
15000 cycles IEC 947-1 Annex K ed 5.2
Control Type:
toggle
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Color:
Gray RAL 7016)
Environmental Disclosure:
ENVPEP1610005EN
Rohs Exemption Information:
Yes
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
California Proposition 65:
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz UL 489
Circuit Breaker Application:
HACR rated
Sustainable Offer Status:
Green Premium product
Trip Unit Name:
TM-D
Standards:
NMX J-266 || CSA C22.2 No 5 || NEMA AB1 || UL 489 || GB 14048.2 || EN/IEC 60947-5-1 || EN/IEC 60947-2
Height:
137 mm
Electrical Connection:
terminal nut, ON and OFF end
Connection Pitch:
27 mm
Number Of Slots:
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in) || 1 alarm switch SD plug-in)
Device Short Name:
BJ 100
Product Name:
PowerPact B
Suitability For Isolation:
yes IEC 60947-2
Breaking Capacity:
100 kA 208Y/120 V AC 50/60 Hz UL 489 || 100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480/277 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600Y/347 V AC 50/60 Hz UL 489 || 50 kA 250 V DC UL 489
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
9 Mm Pitches:
12
Local Signalling:
presence of auxiliary contacts flag green)
Network Frequency:
50/60 Hz
Eu Rohs Directive:
Compliant with Exemptions
Width:
108 mm
Line Rated Current:
100-100 A
Brochure:
View
Catalog:
View
Datasheet: