Schneider Electric BJL36050LU Molded Case Circuit Brkr 600Y/347V 50A

(No reviews yet) Write a Review
SKU:
BJL36050LU
UPC:
3606481149725
Condition:
New
Connection Pitch:
27 mm
Quantity Per Set:
set of 1
Continuous Current Rating:
0.8
Electrical Connection:
Everlink lug, line || Everlink lug, load
Product Or Component Type:
circuit breaker
Eu Rohs Directive:
Compliant with Exemptions
Device Application:
distribution
Utilisation Category:
category A
Pvc Free:
Yes
Mounting Mode:
clip-on 35 mm symmetrical DIN rail) || by screws plate)
Ip Degree Of Protection:
front cover IP40 IEC 60529
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz UL 489
Sustainable Offer Status:
Green Premium product
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Mercury Free:
Yes
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
Trip Unit Technology:
thermal-magneticTM-D,
Ambient Air Temperature For Operation:
-25-70 °C
Color:
Gray RAL 7016)
Breaking Capacity:
100 kA 208Y/120 V AC 50/60 Hz UL 489 || 100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480/277 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600Y/347 V AC 50/60 Hz UL 489 || 50 kA 250 V DC UL 489
Number Of Slots:
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in) || 1 alarm switch SD plug-in)
Quality Labels:
CE
Circularity Profile:
N/A
Ik Degree Of Protection:
IK07 IEC 62262
Wire Stripping Length:
20 mm
Standards:
EN/IEC 60947-5-1 || NEMA AB1 || EN/IEC 60947-2 || UL 489 || GB 14048.2 || NMX J-266 || CSA C22.2 No 5
Environmental Disclosure:
ENVPEP1610005EN
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
Product Name:
PowerPact B
9 Mm Pitches:
9
Network Frequency:
50/60 Hz
Protected Poles Description:
3t
Mechanical Durability:
15000 cycles IEC 947-1 Annex K ed 5.2
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Net Weight:
1.074 kg
Pollution Degree:
3 IEC 60947-1
Depth:
80 mm
Range:
PowerPact
Suitability For Isolation:
yes IEC 60947-2
Awg Gauge:
AWG 6...AWG 2/0 fine stranded aluminium/copper || AWG 14...AWG 3/0 rigid or stranded aluminium/copper
Poles Description:
3P
Local Signalling:
presence of auxiliary contacts flag green)
Operating Altitude:
6561.68 ft (2000 m) without derating || 5000 m with derating
Halogen Content Performance:
Halogen free product
Circuit Breaker Application:
HACR rated
Width:
81 mm
Device Short Name:
BJ 050
Control Type:
toggle
Height:
137 mm
[Ics] Rated Service Breaking Capacity:
100 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 25 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 2.5 kA 690 V AC 50/60 Hz IEC 60947-2 || 65 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 65 kA 440 V AC 50/60 Hz IEC 60947-2
Tightening Torque:
5-5 N.m 2.5-16 mm² (AWG 14...AWG 4) || 9-9 N.m 25-95 mm² (AWG 3...AWG 3/0)
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Trip Unit Name:
TM-D
Line Rated Current:
50-50 A
Rohs Exemption Information:
Yes
Ambient Air Temperature For Storage:
-50-85 °C
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Breaking Capacity Code:
J
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric BJL36050LU Molded Case Circuit Brkr 600Y/347V 50A
  • Schneider Electric BJL36050LU Molded Case Circuit Brkr 600Y/347V 50A
  • Schneider Electric BJL36050LU Molded Case Circuit Brkr 600Y/347V 50A
$2,797.50

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 25kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. This circuit breaker's unit mount construction features traditional back pan mounting with screws or integrated DIN rail mounting for installation flexibility. This unit features EverLink lugs, a patented design to reduce loosening of cables over time, on both termination ends. The EverLink lug has a control wire terminal on the line side. This PowerPacT B, 50A, 3 pole, circuit breaker has a breaking capacity of 25kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose