Schneider Electric EDB24020SA Miniature Circuit Breaker 480Y/277V 20A

(No reviews yet) Write a Review
SKU:
EDB24020SA
UPC:
7.85901E+11
Condition:
New
Local Signalling:
trip indicator
Circuit Breaker Application:
HID rated || HACR rated
Range Of Product:
125 A Frame EDB-EGB-EJB
Number Of Spaces Required:
3
Number Of Spaces:
3
Height:
5.66 in
Device Short Name:
EDB
Line Rated Current:
20 A
Mercury Free:
Yes
Ambient Air Temperature For Operation:
40 °C
Net Weight:
3 lb(US)
Device Composition:
shunt trip
Product Certifications:
cULus
Trip Unit Rating:
875-875 A
Depth:
4.05 in
Product Or Component Type:
miniature circuit-breaker
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Width:
2.94 in
Breaking Capacity:
18 kA 277 V AC || 25 kA 240 V AC || 18 kA 480Y/277 V AC || 25 kA 120 V AC || 25 kA 120/240 V AC
[Ue] Rated Operational Voltage:
480Y/277 V AC
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Mounting Mode:
bolt-on
Breaking Capacity Code:
D
Electrical Connection:
lugs aluminium
Module Type:
E-Frame
Number Of Poles:
2
Awg Gauge:
AWG 12...AWG 6 aluminium || AWG 14...AWG 6 copper
Protection Type:
overload || short-circuit
Holding Current:
270 A
Tightening Torque:
3.4-3.4 N.m 2.5-16 mm² (AWG 14...AWG 6)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Rohs Exemption Information:
Yes
Warranty:
18 months
Product Destination:
NF panelboard
Trip Unit Technology:
thermal-magnetic
  • Schneider Electric EDB24020SA Miniature Circuit Breaker 480Y/277V 20A
  • Schneider Electric EDB24020SA Miniature Circuit Breaker 480Y/277V 20A
$1,291.00

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 20A, 2 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 25 kA max interrupt rating at 120 VAC. This device has a hold current of 270A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 875A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This one includes a shunt trip. This breaker was calibrated for 40 degrees C. This product is UL Listed as High Intensity Discharge. HACR rated.
View AllClose