Schneider Electric EDB24030 Miniature Circuit Breaker 480Y/277V 30A

(No reviews yet) Write a Review
SKU:
EDB24030
UPC:
785901879046
Condition:
New
Mounting Mode:
bolt-on
Rohs Exemption Information:
Yes
Circuit Breaker Application:
HID rated || HACR rated
Product Or Component Type:
miniature circuit-breaker
Trip Unit Technology:
thermal-magnetic
Line Rated Current:
30 A
Electrical Connection:
lugs aluminium
Product Destination:
NF panelboard
Holding Current:
270 A
Mercury Free:
Yes
Product Certifications:
cULus
Height:
5.66 in
Number Of Poles:
2
Number Of Spaces:
2
Tightening Torque:
3.4-3.4 N.m 2.5-16 mm² (AWG 14...AWG 6)
Ambient Air Temperature For Operation:
40 °C
Width:
1.96 in
Depth:
4.05 in
[Ue] Rated Operational Voltage:
480Y/277 V AC
Protection Type:
short-circuit || overload
Breaking Capacity Code:
D
Device Short Name:
EDB
Local Signalling:
trip indicator
Net Weight:
3 lb(US)
Module Type:
E-Frame
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Range Of Product:
125 A Frame EDB-EGB-EJB
Awg Gauge:
AWG 12...AWG 6 aluminium || AWG 14...AWG 6 copper
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Warranty:
18 months
Trip Unit Rating:
875-875 A
Number Of Spaces Required:
2
Breaking Capacity:
18 kA 277 V AC || 25 kA 240 V AC || 18 kA 480Y/277 V AC || 25 kA 120 V AC || 25 kA 120/240 V AC
$536.00

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This device is a 2 pole bolt-on breaker that is rated at 30 A at a system voltage of 480Y/277 VAC and the breaker is UL Listed as well as CSA rated. This E-Frame breaker has thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. This specific breaker is HID rated, HACR rated. The breaker has aluminium lugs which have a terminal lug rating of AWG 12...AWG 6 (aluminium) and AWG 14...AWG 6 (copper). This E-frame breaker breaking capacity has been tested a numerous voltages but at two voltages the capacity is 18 kA at 480Y/277 VAC and 25 kA at 120/240 VAC. This device has a hold current of 270 A which is the maxiumum current the breaker can be held to ensure it will trip and a trip current of 875A which is the current value when the breaker is guaranteed to trip. The circuit breaker has a height of 5.66 in, width of 1.96 in and a depth of 4.05 in. This breaker was calibrated for 40 degrees C. This product is UL Listed as High Intensity Discharge. HACR rated.
View AllClose