Schneider Electric EDB36060 Molded Case Circuit Breaker 600V 60A

(No reviews yet) Write a Review
SKU:
EDB36060
UPC:
785901235620
Condition:
New
Module Type:
E-Frame
Trip Unit Rating:
1800-1800 A
Number Of Spaces:
3
Protection Type:
short-circuit || overload
Product Destination:
NF panelboard
Height:
5.66 in
Net Weight:
4 lb(US)
Circuit Breaker Application:
HACR rated
Width:
2.94 in
Warranty:
18 months
Trip Unit Technology:
thermal-magnetic
Number Of Spaces Required:
3
Range Of Product:
125 A Frame EDB-EGB-EJB
Product Certifications:
cULus
Mounting Mode:
bolt-on
Breaking Capacity:
14 kA 600Y/347 V AC
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Holding Current:
630 A
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Breaking Capacity Code:
D
Electrical Connection:
lugs aluminium
Number Of Poles:
3
Device Short Name:
EDB
Mercury Free:
Yes
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
[Ue] Rated Operational Voltage:
600Y/347 V AC
Tightening Torque:
3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0)
Local Signalling:
trip indicator
Rohs Exemption Information:
Yes
Awg Gauge:
AWG 12...AWG 2/0 aluminium || AWG 14...AWG 2/0 copper
Depth:
4.05 in
Line Rated Current:
60 A
Ambient Air Temperature For Operation:
40 °C
Product Or Component Type:
circuit-breaker
  • Schneider Electric EDB36060 Molded Case Circuit Breaker 600V 60A
  • Schneider Electric EDB36060 Molded Case Circuit Breaker 600V 60A
  • Schneider Electric EDB36060 Molded Case Circuit Breaker 600V 60A
$669.00

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 60A, 3 pole, and has an operating voltage of 600Y/347 VAC. It also provides a 25 kA max interrupt rating at 120 VAC. This device has a hold current of 630A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 1800A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This breaker was calibrated for 40 degrees C. HACR rated.
View AllClose