Schneider Electric EGB36050 Miniature Circuit Breaker 600V 50A

(No reviews yet) Write a Review
SKU:
EGB36050
UPC:
785901235576
Condition:
New
Local Signalling:
trip indicator
Rohs Exemption Information:
Yes
Depth:
4.05 in
Warranty:
18 months
Line Rated Current:
50 A
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Device Short Name:
EGB
Number Of Spaces:
3
Width:
2.94 in
Protection Type:
short-circuit || overload
Circuit Breaker Application:
HACR rated
Height:
5.66 in
Product Certifications:
cULus
Awg Gauge:
AWG 12...AWG 2/0 aluminium || AWG 14...AWG 2/0 copper
Range Of Product:
125 A Frame EDB-EGB-EJB
Mercury Free:
Yes
Breaking Capacity Code:
G
Ambient Air Temperature For Operation:
40 °C
Net Weight:
4 lb(US)
Breaking Capacity:
18 kA 600Y/347 V AC
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Number Of Poles:
3
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Module Type:
E-Frame
Trip Unit Technology:
thermal-magnetic
Mounting Mode:
bolt-on
[Ue] Rated Operational Voltage:
600Y/347 V AC
Product Or Component Type:
circuit-breaker
Holding Current:
630 A
Trip Unit Rating:
1800-1800 A
Product Destination:
NF panelboard
Number Of Spaces Required:
3
Tightening Torque:
3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0)
Electrical Connection:
lugs aluminium
Brochure:
View
Catalog:
View
Datasheet:
View
$1,131.00

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 50A, 3 pole, and has an operating voltage of 600Y/347 VAC. It also provides a 65 kA max interrupt rating at 120 VAC. This device has a hold current of 630A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 1800A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This breaker was calibrated for 40 degrees C. This product is UL Listed as High Intensity Discharge. HACR rated.
View AllClose