Schneider Electric EJB14020EPD Miniature Circuit Breaker 277V 20A

(No reviews yet) Write a Review
SKU:
EJB14020EPD
UPC:
785901484509
Condition:
New
Holding Current:
270 A
Mounting Mode:
bolt-on
Local Signalling:
trip indicator
Line Rated Current:
20 A
Rohs Exemption Information:
Yes
Breaking Capacity Code:
J
Earth-Leakage Sensitivity:
30 mA
Number Of Poles:
1
Protection Type:
overload || short-circuit
Number Of Spaces:
2
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Trip Unit Rating:
875-875 A
Earth-Leakage Protection Class:
class B
Width:
1.96 in
Module Type:
E-Frame
Trip Unit Technology:
thermal-magnetic
Electrical Connection:
lugs aluminium
Warranty:
18 months
Depth:
4.05 in
Number Of Spaces Required:
2
Circuit Breaker Application:
HACR rated || Switching Duty rated || HID rated
[Ue] Rated Operational Voltage:
277 V AC
Height:
6.64 in
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Mercury Free:
Yes
Product Destination:
NF panelboard
Ambient Air Temperature For Operation:
40 °C
Product Or Component Type:
miniature circuit-breaker
Breaking Capacity:
65 kA 240 V AC || 65 kA 277 V AC || 100 kA 120 V AC || 65 kA 120/240 V AC
Device Short Name:
EJB
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Product Certifications:
cULus
Net Weight:
2 lb(US)
Tightening Torque:
3.4-3.4 N.m 2.5-16 mm² (AWG 14...AWG 6)
Awg Gauge:
AWG 14...AWG 6 copper || AWG 12...AWG 4 aluminium
Range Of Product:
125 A Frame EDB-EGB-EJB
Brochure:
View
Datasheet:
View
$1,409.00

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 20A, 1 pole, and has an operating voltage of 277 VAC. It also provides a 100 kA max interrupt rating at 120 VAC. This device has a hold current of 270A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 875A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This one includes 30 mA ground protection. This breaker was calibrated for 40 degrees C. This product is UL Listed as Switching duty and High Intensity Discharge. HACR rated.
View AllClose