Schneider Electric GV2ME043 Tesys Spring Term. Mcb

(No reviews yet) Write a Review
SKU:
GV2ME043
UPC:
3.38911E+12
Condition:
New
Net Weight:
0.28 kg
Circularity Profile:
ENVEOLI121004
Ik Degree Of Protection:
IK04
Rated Duty:
continuous IEC 60947-4-1
Range:
TeSys Deca
Line Rated Current:
0.63 A
Product Certifications:
CCC || UL || CSA || EAC || ATEX || LROS (Lloyds register of shipping) || BV || RINA || DNV-GL || UKCA
Environmental Disclosure:
ENVPEP121004
Width:
45 mm
Operating Altitude:
6561.68 ft (2000 m)
Height:
101 mm
Trip Unit Technology:
thermal-magnetic
Electrical Durability:
100000 cycles AC-3 415 V In || 100000 cycles AC-3e 415 V In
Control Type:
push-button
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1 || AC-3e IEC 60947-4-1
Fire Resistance:
960 °C IEC 60695-2-11
Phase Failure Sensitivity:
yes IEC 60947-4-1
Product Name:
TeSys GV2 || TeSys Deca
Fixing Mode:
35 mm symmetrical DIN rail clipped || panel screwed with adaptor plate)
Network Type:
AC
[Ics] Rated Service Short-Circuit Breaking Capacity:
100 % 230/240 V AC 50/60 Hz IEC 60947-2 || 100 % 400/415 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 100 % 500 V AC 50/60 Hz IEC 60947-2 || 100 % 690 V AC 50/60 Hz IEC 60947-2
Mechanical Durability:
100000 cycles
Ambient Air Temperature For Operation:
-20-60 °C
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Suitability For Isolation:
yes IEC 60947-1 § 7-1-6
Mechanical Robustness:
shocks 30 Gn for 11 ms || vibrations 5 Gn, 5...150 Hz
Ambient Air Temperature For Storage:
-40-80 °C
California Proposition 65:
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Ip Degree Of Protection:
IP20 IEC 60529
Rohs Exemption Information:
Yes
Power Dissipation Per Pole:
2.5 W
Standards:
EN/IEC 60947-2 || EN/IEC 60947-4-1
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
Climatic Withstand:
IACS E10
Device Short Name:
GV2ME
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Eu Rohs Directive:
Compliant with Exemptions
Color:
dark grey
Depth:
78.5 mm
Sustainable Offer Status:
Green Premium product
Thermal Protection Adjustment Range:
0.4-63 A IEC 60947-4-1
[Ui] Rated Insulation Voltage:
690 V AC 50/60 Hz IEC 60947-2
Network Frequency:
50/60 Hz IEC 60947-4-1
Poles Description:
3P
Warranty:
18 months
Product Or Component Type:
motor circuit breaker
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Motor Power Kw:
0.12-0.12 kW 400/415 V AC 50/60 Hz || 0.18-0.18 kW 400/415 V AC 50/60 Hz
Device Application:
motor protection
Mercury Free:
Yes
[Ith] Conventional Free Air Thermal Current:
0.63 A IEC 60947-4-1
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947-2
Breaking Capacity:
100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 690 V AC 50/60 Hz IEC 60947-2
Magnetic Tripping Current:
8-8 A
Datasheet:
View
  • Schneider Electric GV2ME043 Tesys Spring Term. Mcb
  • Schneider Electric GV2ME043 Tesys Spring Term. Mcb
$180.00

Description

TeSys GV motor circuit breaker, 3 poles (3P), 0.63A/690V, for 3-phase motor applications 0.12-0.18kW@400V. It provides a thermal-magnetic protection with a thermal setting range 0.4-0.63A, magnetic tripping at 13xIn, high breaking capacity Icu 100kA@400V. Connection by spring terminals. Start-stop control by push-button guaranteed for 100 000 cycles AC-3. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
View AllClose