Schneider Electric GV2ME07 Tesys M-Cb Tho/Mag 1.6-2.5A Rocker
Schneider Electric
$180.00
The GV2 manual starter and protector provides manual isolation, manual motor control, and thermal overcurrent protection in one compact unit. The basic motor starter GV2ME controls motors with full load currents up to 32 A. The manual starter is three pole with horsepower ratings. The manual starter is operated by push buttons. The Class 10 ambient compensated thermal over current is adjustable from 1.6 ampere to 2.5 ampere. This device has screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
- Network Frequency:
- 50/60 Hz IEC 60947-4-1
- Breaking Capacity:
- 100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 3 kA Icu 690 V AC 50/60 Hz IEC 60947-2
- Device Short Name:
- GV2ME
- Ip Degree Of Protection:
- IP20 IEC 60529
- [Ith] Conventional Free Air Thermal Current:
- 2.5 A IEC 60947-4-1
- Eu Rohs Directive:
- Compliant with Exemptions
- Line Rated Current:
- 2.5 A
- Climatic Withstand:
- IACS E10
- Rohs Exemption Information:
- Yes
- Circularity Profile:
- ENVEOLI121004
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Mechanical Robustness:
- shocks 30 Gn for 11 ms || vibrations 5 Gn, 5...150 Hz
- Power Dissipation Per Pole:
- 2.5 W
- Control Type:
- push-button
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Sustainable Offer Status:
- Green Premium product
- Suitability For Isolation:
- yes IEC 60947-1 § 7-1-6
- Ambient Air Temperature For Operation:
- -20-60 °C
- Width:
- 45 mm
- Net Weight:
- 0.26 kg
- Utilisation Category:
- category A IEC 60947-2 || AC-3 IEC 60947-4-1 || AC-3e IEC 60947-4-1
- Tightening Torque:
- 1.7 N.m screw clamp terminal
- Trip Unit Technology:
- thermal-magnetic
- [Ui] Rated Insulation Voltage:
- 690 V AC 50/60 Hz IEC 60947-2
- Color:
- dark grey
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
- Product Certifications:
- CCC || UL || CSA || EAC || ATEX || LROS (Lloyds register of shipping) || BV || RINA || DNV-GL || UKCA
- Thermal Protection Adjustment Range:
- 1.6-2.5 A IEC 60947-4-1
- Height:
- 89 mm
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-2
- Operating Altitude:
- 6561.68 ft (2000 m)
- Product Name:
- TeSys GV2 || TeSys Deca
- Warranty:
- 18 months
- Network Type:
- AC
- Device Application:
- motor protection
- Standards:
- EN/IEC 60947-2 || EN/IEC 60947-4-1
- Product Or Component Type:
- motor circuit breaker
- Ambient Air Temperature For Storage:
- -40-80 °C
- Environmental Disclosure:
- ENVPEP121004
- Range:
- TeSys Deca
- [Ics] Rated Service Short-Circuit Breaking Capacity:
- 100 % 230/240 V AC 50/60 Hz IEC 60947-2 || 100 % 400/415 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 100 % 500 V AC 50/60 Hz IEC 60947-2 || 75 % 690 V AC 50/60 Hz IEC 60947-2
- Fire Resistance:
- 960 °C IEC 60695-2-11
- Magnetic Tripping Current:
- 33.5-33.5 A
- Poles Description:
- 3P
- Phase Failure Sensitivity:
- yes IEC 60947-4-1
- Motor Power Kw:
- 0.75-0.75 kW 400/415 V AC 50/60 Hz || 1.1-1.1 kW 500 V AC 50/60 Hz || 1.5-1.5 kW 690 V AC 50/60 Hz
- Ik Degree Of Protection:
- IK04
- Depth:
- 78.5 mm
- Fixing Mode:
- 35 mm symmetrical DIN rail clipped || panel screwed with adaptor plate)
- Electrical Durability:
- 100000 cycles AC-3 415 V In || 100000 cycles AC-3e 415 V In
- Mechanical Durability:
- 100000 cycles
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947-2
- Rated Duty:
- continuous IEC 60947-4-1
- Mercury Free:
- Yes
- Datasheet:
- View