TeSys GV motor circuit breaker, 3 poles (3P), 4A/690V, for 3-phase motor applications 1.1-1.5kW@400V. It provides a thermal-magnetic protection with a thermal setting range 2.5-4A, magnetic tripping at 13xIn, high breaking capacity Icu 100kA@400V. Connection by lugs. Start-stop control by push-button guaranteed for 100 000 cycles AC-3. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
- Climatic Withstand:
- IACS E10
- Ambient Air Temperature For Operation:
- -20-60 °C
- Rohs Exemption Information:
- Yes
- Network Frequency:
- 50/60 Hz IEC 60947-4-1
- Line Rated Current:
- 0.166666666666667
- Connection Pitch:
- 13.5 mm without spreader
- Environmental Disclosure:
- ENVPEP121004
- [Ics] Rated Service Short-Circuit Breaking Capacity:
- 100 % 230/240 V AC 50/60 Hz IEC 60947-2 || 100 % 400/415 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 100 % 500 V AC 50/60 Hz IEC 60947-2 || 75 % 690 V AC 50/60 Hz IEC 60947-2
- Breaking Capacity:
- 100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 3 kA Icu 690 V AC 50/60 Hz IEC 60947-2
- Width:
- 45 mm
- Power Dissipation Per Pole:
- 2.5 W
- Eu Rohs Directive:
- Compliant with Exemptions
- Control Type:
- push-button
- Ambient Air Temperature For Storage:
- -40-80 °C
- Color:
- dark grey
- Utilisation Category:
- category A IEC 60947-2 || AC-3 IEC 60947-4-1 || AC-3e IEC 60947-4-1
- Product Certifications:
- CCC || UL || CSA || EAC || ATEX || LROS (Lloyds register of shipping) || BV || RINA || DNV-GL || UKCA
- Mechanical Robustness:
- shocks 30 Gn for 11 ms || vibrations 5 Gn, 5...150 Hz
- Phase Failure Sensitivity:
- yes IEC 60947-4-1
- Circularity Profile:
- ENVEOLI121004
- [Ith] Conventional Free Air Thermal Current:
- 4 A IEC 60947-4-1
- Height:
- 89 mm
- Depth:
- 78.5 mm
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Standards:
- EN/IEC 60947-2 || EN/IEC 60947-4-1
- Suitability For Isolation:
- yes IEC 60947-1 § 7-1-6
- Fixing Mode:
- 35 mm symmetrical DIN rail clipped || panel screwed with adaptor plate)
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-2
- Product Or Component Type:
- motor circuit breaker
- Ip Degree Of Protection:
- IP20 IEC 60529
- Trip Unit Technology:
- thermal-magnetic
- [Ui] Rated Insulation Voltage:
- 690 V AC 50/60 Hz IEC 60947-2
- Magnetic Tripping Current:
- 51-51 A
- Poles Description:
- 3P
- Device Short Name:
- GV2ME
- Network Type:
- AC
- Fire Resistance:
- 960 °C IEC 60695-2-11
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
- Warranty:
- 18 months
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Rated Duty:
- continuous IEC 60947-4-1
- Product Name:
- TeSys GV2 || TeSys Deca
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947-2
- Net Weight:
- 0.26 kg
- Motor Power Kw:
- 1.1-1.1 kW 400/415 V AC 50/60 Hz || 1.5-1.5 kW 400/415 V AC 50/60 Hz || 1.5-1.5 kW 500 V AC 50/60 Hz || 2.2-2.2 kW 500 V AC 50/60 Hz || 3-3 kW 690 V AC 50/60 Hz || 2.2-2.2 kW 690 V AC 50/60 Hz
- Operating Altitude:
- 6561.68 ft (2000 m)
- Electrical Durability:
- 100000 cycles AC-3 415 V In || 100000 cycles AC-3e 415 V In
- Range:
- TeSys Deca
- Ik Degree Of Protection:
- IK04
- Mercury Free:
- Yes
- Sustainable Offer Status:
- Green Premium product
- Thermal Protection Adjustment Range:
- 2.5-4 A IEC 60947-4-1
- Device Application:
- motor protection
- Mechanical Durability:
- 100000 cycles
- Catalog:
- View