Schneider Electric GV2ME10 Tesys M-Cb Tho/Mag 4-6.3A Rocker
Schneider Electric
$180.00
The GV2 manual starter and protector provides manual isolation, manual motor control, and thermal overcurrent protection in one compact unit. The basic motor starter GV2ME controls motors with full load currents up to 32 A. The manual starter is three pole with horsepower ratings. The manual starter is operated by push buttons. The Class 10 ambient compensated thermal over current is adjustable from 4 ampere to 6.3 ampere. This device has screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Mechanical Durability:
- 100000 cycles
- [Ics] Rated Service Short-Circuit Breaking Capacity:
- 100 % 230/240 V AC 50/60 Hz IEC 60947-2 || 100 % 400/415 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 100 % 500 V AC 50/60 Hz IEC 60947-2 || 75 % 690 V AC 50/60 Hz IEC 60947-2
- Poles Description:
- 3P
- Color:
- dark grey
- Fixing Mode:
- 35 mm symmetrical DIN rail clipped || panel screwed with adaptor plate)
- Depth:
- 78.5 mm
- Operating Altitude:
- 6561.68 ft (2000 m)
- Trip Unit Technology:
- thermal-magnetic
- Power Dissipation Per Pole:
- 2.5 W
- Suitability For Isolation:
- yes IEC 60947-1 § 7-1-6
- Motor Power Kw:
- 2.2-2.2 kW 400/415 V AC 50/60 Hz || 3-3 kW 500 V AC 50/60 Hz || 4-4 kW 690 V AC 50/60 Hz
- Network Type:
- AC
- Net Weight:
- 0.26 kg
- Height:
- 89 mm
- Tightening Torque:
- 1.7 N.m screw clamp terminal
- Warranty:
- 18 months
- Sustainable Offer Status:
- Green Premium product
- Circularity Profile:
- ENVEOLI121004
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Mechanical Robustness:
- shocks 30 Gn for 11 ms || vibrations 5 Gn, 5...150 Hz
- Ik Degree Of Protection:
- IK04
- Ambient Air Temperature For Storage:
- -40-80 °C
- Rohs Exemption Information:
- Yes
- Environmental Disclosure:
- ENVPEP121004
- Range:
- TeSys Deca
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947-2
- Phase Failure Sensitivity:
- yes IEC 60947-4-1
- [Ith] Conventional Free Air Thermal Current:
- 6.3 A IEC 60947-4-1
- Rated Duty:
- continuous IEC 60947-4-1
- Control Type:
- push-button
- Device Short Name:
- GV2ME
- Fire Resistance:
- 960 °C IEC 60695-2-11
- Product Or Component Type:
- motor circuit breaker
- Ambient Air Temperature For Operation:
- -20-60 °C
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-2
- Standards:
- EN/IEC 60947-2 || EN/IEC 60947-4-1
- Thermal Protection Adjustment Range:
- 4-6.3 A IEC 60947-4-1
- Magnetic Tripping Current:
- 78-78 A
- Ip Degree Of Protection:
- IP20 IEC 60529
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Electrical Durability:
- 100000 cycles AC-3 415 V In || 100000 cycles AC-3e 415 V In
- Device Application:
- motor protection
- Eu Rohs Directive:
- Compliant with Exemptions
- [Ui] Rated Insulation Voltage:
- 690 V AC 50/60 Hz IEC 60947-2
- Product Name:
- TeSys GV2 || TeSys Deca
- Utilisation Category:
- category A IEC 60947-2 || AC-3 IEC 60947-4-1 || AC-3e IEC 60947-4-1
- Network Frequency:
- 50/60 Hz IEC 60947-4-1
- Product Certifications:
- CCC || UL || CSA || EAC || ATEX || LROS (Lloyds register of shipping) || BV || RINA || DNV-GL || UKCA
- Breaking Capacity:
- 100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 3 kA Icu 690 V AC 50/60 Hz IEC 60947-2
- Line Rated Current:
- 6.3 A
- Width:
- 45 mm
- Mercury Free:
- Yes
- Climatic Withstand:
- IACS E10
- Catalog:
- View
- Datasheet:
- View