Schneider Electric GV2ME20 Tesys M-Cb Tho/Mag 13-18A Rocker
Schneider Electric
$224.00
The GV2 manual starter and protector provides manual isolation, manual motor control, and thermal overcurrent protection in one compact unit. The basic motor starter GV2ME controls motors with full load currents up to 32 A. The manual starter is three pole with horsepower ratings. The manual starter is operated by push buttons. The Class 10 ambient compensated thermal over current is adjustable from 13 ampere to 18 ampere. This device has screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
- Ambient Air Temperature For Operation:
- -20-60 °C
- Control Type:
- push-button
- Utilisation Category:
- category A IEC 60947-2 || AC-3 IEC 60947-4-1 || AC-3e IEC 60947-4-1
- Mechanical Durability:
- 100000 cycles
- Line Rated Current:
- 18 A
- Depth:
- 78.5 mm
- Poles Description:
- 3P
- Ip Degree Of Protection:
- IP20 IEC 60529
- Ambient Air Temperature For Storage:
- -40-80 °C
- Power Dissipation Per Pole:
- 2.5 W
- Environmental Disclosure:
- ENVPEP121004
- Device Short Name:
- GV2ME
- Eu Rohs Directive:
- Compliant with Exemptions
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947-2
- Operating Altitude:
- 6561.68 ft (2000 m)
- Rohs Exemption Information:
- Yes
- Net Weight:
- 0.26 kg
- Product Certifications:
- CCC || UL || CSA || EAC || ATEX || LROS (Lloyds register of shipping) || BV || RINA || DNV-GL || UKCA
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-2
- Trip Unit Technology:
- thermal-magnetic
- Climatic Withstand:
- IACS E10
- Ik Degree Of Protection:
- IK04
- Fire Resistance:
- 960 °C IEC 60695-2-11
- Phase Failure Sensitivity:
- yes IEC 60947-4-1
- Rated Duty:
- continuous IEC 60947-4-1
- Breaking Capacity:
- 100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 || 15 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 8 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 6 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 3 kA Icu 690 V AC 50/60 Hz IEC 60947-2
- Suitability For Isolation:
- yes IEC 60947-1 § 7-1-6
- Sustainable Offer Status:
- Green Premium product
- Network Type:
- AC
- Standards:
- EN/IEC 60947-2 || EN/IEC 60947-4-1
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- [Ui] Rated Insulation Voltage:
- 690 V AC 50/60 Hz IEC 60947-2
- Network Frequency:
- 50/60 Hz IEC 60947-4-1
- [Ith] Conventional Free Air Thermal Current:
- 18 A IEC 60947-4-1
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Fixing Mode:
- 35 mm symmetrical DIN rail clipped || panel screwed with adaptor plate)
- Magnetic Tripping Current:
- 223-223 A
- Height:
- 89 mm
- Circularity Profile:
- ENVEOLI121004
- Warranty:
- 18 months
- Thermal Protection Adjustment Range:
- 13-18 A IEC 60947-4-1
- Electrical Durability:
- 100000 cycles AC-3 415 V In || 100000 cycles AC-3e 415 V In
- Product Name:
- TeSys GV2 || TeSys Deca
- Product Or Component Type:
- motor circuit breaker
- Width:
- 45 mm
- [Ics] Rated Service Short-Circuit Breaking Capacity:
- 100 % 230/240 V AC 50/60 Hz IEC 60947-2 || 50 % 400/415 V AC 50/60 Hz IEC 60947-2 || 50 % 440 V AC 50/60 Hz IEC 60947-2 || 75 % 500 V AC 50/60 Hz IEC 60947-2 || 75 % 690 V AC 50/60 Hz IEC 60947-2
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Tightening Torque:
- 1.7 N.m screw clamp terminal
- Motor Power Kw:
- 7.5-7.5 kW 400/415 V AC 50/60 Hz || 9-9 kW 500 V AC 50/60 Hz || 15-15 kW 690 V AC 50/60 Hz
- Mechanical Robustness:
- shocks 30 Gn for 11 ms || vibrations 5 Gn, 5...150 Hz
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
- Device Application:
- motor protection
- Mercury Free:
- Yes
- Range:
- TeSys Deca
- Color:
- dark grey
- Catalog:
- View
- Datasheet:
- View