Schneider Electric GV2P16 Tesys Motor Circuit Breaker

(No reviews yet) Write a Review
SKU:
GV2P16
UPC:
3389110213508
Condition:
New
Mechanical Robustness:
shocks 30 Gn for 11 ms || vibrations 5 Gn, 5...150 Hz
Range:
TeSys Deca
Magnetic Tripping Current:
170-170 A
Operating Altitude:
6561.68 ft (2000 m)
Fixing Mode:
35 mm symmetrical DIN rail clipped || panel screwed with 2 x M4 screws)
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1 || AC-3e IEC 60947-4-1
[Ics] Rated Service Short-Circuit Breaking Capacity:
100 % 230/240 V AC 50/60 Hz IEC 60947-2 || 100 % 400/415 V AC 50/60 Hz IEC 60947-2 || 75 % 440 V AC 50/60 Hz IEC 60947-2 || 75 % 500 V AC 50/60 Hz IEC 60947-2 || 100 % 690 V AC 50/60 Hz IEC 60947-2
Ik Degree Of Protection:
IK04
Climatic Withstand:
IACS E10
Product Or Component Type:
motor circuit breaker
Circularity Profile:
ENVEOLI2211002
Environmental Disclosure:
ENVPEP2211002
Depth:
97 mm
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Network Frequency:
50/60 Hz IEC 60947-4-1
Poles Description:
3P
Motor Power Kw:
5.5-5.5 kW 400/415 V AC 50/60 Hz || 7.5-7.5 kW 500 V AC 50/60 Hz || 9-9 kW 690 V AC 50/60 Hz || 11-11 kW 690 V AC 50/60 Hz
Device Application:
motor protection
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
Trip Unit Technology:
thermal-magnetic
Network Type:
AC
Tightening Torque:
1.7 N.m screw clamp terminal
Eu Rohs Directive:
Compliant with Exemptions
Line Rated Current:
14 A
Ip Degree Of Protection:
IP20 IEC 60529
Ambient Air Temperature For Operation:
-20-60 °C
Power Dissipation Per Pole:
2.5 W
Color:
dark grey
Rated Duty:
continuous IEC 60947-4-1
Device Short Name:
GV2P
Product Name:
TeSys GV2 || TeSys Deca
Width:
45 mm
Breaking Capacity:
100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 42 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 6 kA Icu 690 V AC 50/60 Hz IEC 60947-2
Phase Failure Sensitivity:
yes IEC 60947-4-1
Standards:
EN/IEC 60947-2 || EN/IEC 60947-4-1
Product Certifications:
CCC || UL || CSA || EAC || ATEX || LROS (Lloyds register of shipping) || BV || RINA || DNV-GL || UKCA
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Suitability For Isolation:
yes IEC 60947-1 § 7-1-6
Control Type:
rotary handle
Ambient Air Temperature For Storage:
-40-80 °C
Electrical Durability:
100000 cycles AC-3 415 V In || 100000 cycles AC-3e 415 V In
Warranty:
18 months
Fire Resistance:
960 °C IEC 60695-2-11
California Proposition 65:
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947-2
Height:
89 mm
[Ui] Rated Insulation Voltage:
690 V AC 50/60 Hz IEC 60947-2
[Ith] Conventional Free Air Thermal Current:
14 A IEC 60947-4-1
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Mechanical Durability:
100000 cycles
Thermal Protection Adjustment Range:
9-14 A IEC 60947-4-1
Catalog:
View
Datasheet:
View
  • Schneider Electric GV2P16 Tesys Motor Circuit Breaker
  • Schneider Electric GV2P16 Tesys Motor Circuit Breaker
$278.00

Description

The GV2 manual starter and protector provides manual isolation, manual motor control, and thermal overcurrent protection in one compact unit. The basic motor starter GV2P controls motors with full load currents up to 32 A. The manual starter is three pole with horsepower ratings. The manual starter is operated by a rotary handle. The Class 10 ambient compensated thermal over current is adjustable from 9 ampere to 14 ampere. This device has screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
View AllClose