Schneider Electric GV3L736 Gv3L Motor Cb Magnetic 73A Lugs

(No reviews yet) Write a Review
SKU:
GV3L736
UPC:
3606481304599
Condition:
New
Magnetic Tripping Current:
1120-1120 A
Fixing Mode:
35 mm symmetrical DIN rail clipped || panel screwed with 3 x M4 screws)
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Utilisation Category:
category A IEC 60947-2
Height:
132 mm
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Mechanical Robustness:
shocks 5 Gn for 11 ms contactor open || shocks 30 Gn for 11 ms contactor closed || vibrations 4 Gn, 5...300 Hz
Depth:
136 mm
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Electrical Durability:
20000 cycles AC-3 415 V In
[Ui] Rated Insulation Voltage:
690 V AC 50/60 Hz IEC 60947-2
Network Type:
AC
Breaking Capacity:
65 kA Icu 230/240 V AC 50/60 Hz || 50 kA Icu 400/415 V AC 50/60 Hz || 50 kA Icu 440 V AC 50/60 Hz || 12 kA Icu 500 V AC 50/60 Hz || 6 kA Icu 690 V AC 50/60 Hz
Product Or Component Type:
motor circuit breaker
[Ics] Rated Service Short-Circuit Breaking Capacity:
100 % 230/240 V AC 50/60 Hz || 60 % 400/415 V AC 50/60 Hz || 60 % 440 V AC 50/60 Hz || 50 % 500 V AC 50/60 Hz || 50 % 690 V AC 50/60 Hz
Circularity Profile:
ENVEOLI060901
Tightening Torque:
6 N.m lugs-ring terminals
Product Certifications:
CCC || UL || CSA || EAC || LROS (Lloyds register of shipping) || BV || ABS || DNV-GL || UKCA
Ip Degree Of Protection:
IP20 IEC 60529
Mercury Free:
Yes
Climatic Withstand:
IACS E10
Standards:
EN/IEC 60947-2 || EN/IEC 60947-4-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1
Eu Rohs Directive:
Compliant with Exemptions
Net Weight:
0.96 kg
Poles Description:
3P
Device Short Name:
GV3L
Ambient Air Temperature For Operation:
-20-60 °C
Environmental Disclosure:
ENVPEP060901
Mechanical Durability:
50000 cycles
Control Type:
rotary handle
Fire Resistance:
960 °C IEC 60695-2-11
Device Application:
motor protection
Range:
TeSys Deca
Motor Power Kw:
37-37 kW 400/415 V AC 50/60 Hz || 45-45 kW 500 V AC 50/60 Hz || 55-55 kW 690 V AC 50/60 Hz
Suitability For Isolation:
yes IEC 60947-1
Warranty:
18 months
Ambient Air Temperature For Storage:
-40-80 °C
Operating Altitude:
9842.52 ft (3000 m)
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947-2
Sustainable Offer Status:
Green Premium product
Trip Unit Technology:
magnetic
Rohs Exemption Information:
Yes
Width:
55 mm
Product Name:
TeSys GV3
Power Dissipation Per Pole:
8 W
Network Frequency:
50/60 Hz
Color:
dark grey
Line Rated Current:
73 A
Connection Pitch:
17.5 mm without spreaders
Datasheet:
View
$555.00

Description

TeSys GV motor circuit breaker, 3 poles (3P), 73A/690V, for 3-phase motor applications 37kW@400V. It provides a magnetic protection with a tripping level at 15xIn, high breaking capacity Icu 50kA@400V. Connection by bars or lugs. Start-stop control by rotary handle guaranteed for 20 000 cycles AC-3. To complete motor protection, use it in association with a lugs connection thermal overload relay LRD3806 (to be ordered separately). Multi standards certified (IEC, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
View AllClose