Schneider Electric GV4PB115S Motbreakgv4Pbul489Th/Mag 115A 100Kaelink

(No reviews yet) Write a Review
SKU:
GV4PB115S
UPC:
3606489868703
Condition:
New
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1
Rohs Exemption Information:
Yes
Mercury Free:
Yes
Operating Altitude:
5000 m
Standards:
EN/IEC 60947-1 || EN/IEC 60947-2 || EN/IEC 60947-4-1 || UL 489 || CSA C22.2 No 5
Rated Duty:
continuous IEC 60947-4-1
Fire Resistance:
960 °C IEC 60695-2-11
Ambient Air Temperature For Storage:
-50-85 °C
Halogen Content Performance:
Halogen free plastic parts product
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
Connections - Terminals:
EverLink BTR screw connectors top) 1 1.5-70 mm² - rigid || EverLink BTR screw connectors top) 1 1.5-50 mm² - flexible || EverLink BTR screw connectors bottom) 1 2.5-95 mm² - rigid || EverLink BTR screw connectors bottom) 1 2.5-70 mm² - flexible
Ip Degree Of Protection:
IP40 IEC 60529
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2 || 600Y/347 V AC 60 Hz UL 489
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Trip Unit Technology:
thermal-magnetic || electronic
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Pvc Free:
Yes
Ik Degree Of Protection:
IK07 IEC 62262
Pollution Degree:
3
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Range:
TeSys Deca
Line Rated Current:
115 A
Width:
81 mm
Power Dissipation Per Pole:
4.6 W
[Ith] Conventional Free Air Thermal Current:
115 A IEC 60947-4-1
Poles Description:
3P
Product Certifications:
IEC || UL || CSA
Operating Position:
any position
Range Of Product:
TeSys GV4
Tightening Torque:
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Eu Rohs Directive:
Compliant with Exemptions
Net Weight:
1.45 kg
Circularity Profile:
ENVEOLI1704004EN
[Ics] Rated Service Short-Circuit Breaking Capacity:
100 % 220/240 V AC 50/60 Hz IEC 60947-2 || 100 % 380/415 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 100 % 500 V AC 50/60 Hz IEC 60947-2 || 100 % 525 V AC 50/60 Hz IEC 60947-2 || 25 % 660/690 V AC 50/60 Hz IEC 60947-2
Climatic Withstand:
IACS E10
Device Short Name:
GV4PB
Suitability For Isolation:
yes IEC 60947-1
Phase Failure Sensitivity:
yes IEC 60947-4-1
Ambient Air Temperature For Operation:
-25-70 °C
Electrical Durability:
10000 cycles AC-3 440 V In/2 || 5000 cycles AC-3 440 V In
Product Or Component Type:
motor circuit breaker
Height:
171 mm
Warranty:
18 months
Depth:
116 mm
Mechanical Robustness:
vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
Device Application:
motor protection
Color:
Gray RAL 7016)
Mechanical Durability:
40000 cycles
Magnetic Tripping Current:
1955-1955 A
Sustainable Offer Status:
Green Premium product
Product Name:
TeSys GV4 || TeSys Deca
Environmental Disclosure:
ENVPEP1704004EN
Breaking Capacity:
100 kA SCCR 240 V AC 60 Hz UL 489 || 65 kA SCCR 480Y/277 V AC 60 Hz UL 489 || 25 kA SCCR 600Y/347 V AC 60 Hz UL 489 || 120 kA Icu 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 380/415 V AC 50/60 Hz IEC 60947-2 || 70 kA Icu 440 V AC 50/60 Hz IEC 609
Control Type:
toggle
Maximum Operating Rate:
25 cyc/h
Catalog:
View
Datasheet:
View
$636.00

Description

TeSys GV motor circuit breaker, 3 poles (3P), 115A/690V, for protection of 3-phase motors 37-55kW@400V. Multifunction circuit breaker UL489 compliant, it provides thermal magnetic protection and advanced motor protection, breaking capacity Icu 100kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 65-115A, a selectable tripping class 10 or 20, rated tripping current 125%, magnetic protection at 17 In. Advanced protections are adjustable with a smartphone using wireless NFC and include short time delay protection Isd with a setting range 5-13 Ir, phase unbalance and loss protection, ground fault protection, locked rotor (jam), long start. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). It can be equiped externally with 1 or 2 auxiliary SDx modules in order to have alarming and fault differentiation. Multi standards certified (IEC, UL 489, CSA C22.2 N°5), Green Premium compliant (RoHS/REACh).
View AllClose