Schneider Electric

Schneider Electric GV4PB12S Motbreakgv4Pbul489Th/Mag 12.5A100Kaelink

(No reviews yet) Write a Review
SKU:
GV4PB12S
UPC:
3606489868666
Condition:
New
Mechanical Robustness:
vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
Breaking Capacity:
100 kA SCCR 240 V AC 60 Hz UL 489 || 65 kA SCCR 480Y/277 V AC 60 Hz UL 489 || 25 kA SCCR 600Y/347 V AC 60 Hz UL 489 || 120 kA Icu 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 380/415 V AC 50/60 Hz IEC 60947-2 || 70 kA Icu 440 V AC 50/60 Hz IEC 609
Net Weight:
1.45 kg
Mechanical Durability:
40000 cycles
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Poles Description:
3P
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Product Certifications:
IEC || UL || CSA
Product Or Component Type:
motor circuit breaker
Eu Rohs Directive:
Compliant with Exemptions
Color:
Gray RAL 7016)
Sustainable Offer Status:
Green Premium product
Ip Degree Of Protection:
IP40 IEC 60529
Control Type:
toggle
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1
Rohs Exemption Information:
Yes
Height:
171 mm
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2 || 600Y/347 V AC 60 Hz UL 489
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Pvc Free:
Yes
[Ics] Rated Service Short-Circuit Breaking Capacity:
100 % 220/240 V AC 50/60 Hz IEC 60947-2 || 100 % 380/415 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 100 % 500 V AC 50/60 Hz IEC 60947-2 || 100 % 525 V AC 50/60 Hz IEC 60947-2 || 25 % 660/690 V AC 50/60 Hz IEC 60947-2
Ik Degree Of Protection:
IK07 IEC 62262
Depth:
116 mm
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
Suitability For Isolation:
yes IEC 60947-1
Trip Unit Technology:
electronic || thermal-magnetic
Fire Resistance:
960 °C IEC 60695-2-11
[Ith] Conventional Free Air Thermal Current:
115 A IEC 60947-4-1
Maximum Operating Rate:
25 cyc/h
Tightening Torque:
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Magnetic Tripping Current:
213-213 A
Product Name:
TeSys GV4 || TeSys Deca
Circularity Profile:
ENVEOLI1704004EN
Power Dissipation Per Pole:
4.6 W
Mercury Free:
Yes
Standards:
EN/IEC 60947-1 || EN/IEC 60947-2 || EN/IEC 60947-4-1 || UL 489 || CSA C22.2 No 5
Width:
81 mm
Device Short Name:
GV4PB
Operating Position:
any position
Operating Altitude:
5000 m
Line Rated Current:
12.5 A
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Warranty:
18 months
Device Application:
motor protection
Range Of Product:
TeSys GV4
Pollution Degree:
3
Ambient Air Temperature For Storage:
-50-85 °C
Climatic Withstand:
IACS E10
Electrical Durability:
40000 cycles AC-3 440 V In/2 || 40000 cycles AC-3 440 V In
Rated Duty:
continuous IEC 60947-4-1
Ambient Air Temperature For Operation:
-25-70 °C
Halogen Content Performance:
Halogen free plastic parts product
Phase Failure Sensitivity:
yes IEC 60947-4-1
Range:
TeSys Deca
Connections - Terminals:
EverLink BTR screw connectors top) 1 1.5-70 mm² - rigid || EverLink BTR screw connectors top) 1 1.5-50 mm² - flexible || EverLink BTR screw connectors bottom) 1 2.5-95 mm² - rigid || EverLink BTR screw connectors bottom) 1 2.5-70 mm² - flexible
Environmental Disclosure:
ENVPEP1704004EN
Datasheet:
View
$508.00

Description

TeSys GV motor circuit breaker, 3 poles (3P), 12.5A/690V, for protection of 3-phase motors 3-5.5kW@400V. Multifunction circuit breaker UL489 compliant, it provides thermal magnetic protection and advanced motor protection, breaking capacity Icu 100kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 5-12.5A, a selectable tripping class 10 or 20, rated tripping current 125%, magnetic protection at 17 In. Advanced protections are adjustable with a smartphone using wireless NFC and include short time delay protection Isd with a setting range 5-13 Ir, phase unbalance and loss protection, ground fault protection, locked rotor (jam), long start. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). It can be equiped externally with 1 or 2 auxiliary SDx modules in order to have alarming and fault differentiation. Multi standards certified (IEC, UL 489, CSA C22.2 N°5), Green Premium compliant (RoHS/REACh).