Schneider Electric

Schneider Electric GVAS116 Tesys Shunt Trip Ten.110V60

(No reviews yet) Write a Review
SKU:
GVAS116
UPC:
3389110343694
Condition:
New
Device Short Name:
GVAS
Rohs Exemption Information:
Yes
Connections - Terminals:
screw clamp terminals 1 1-2.5 mm²solid || screw clamp terminals 2 1-2.5 mm²solid || screw clamp terminals 1 0.75-2.5 mm²flexible without cable end || screw clamp terminals 2 0.75-2.5 mm²flexible without cable end || screw clamp terminals 1 0.75-1
Control Circuit Voltage Limits:
0.7...1.1 Un
Mechanical Durability:
10000 cycles with GV3P and GV3L || 30000 cycles with GV2ME and GV2P
Threshold Tripping Voltage:
0.75...0.2 Un
Net Weight:
0.105 kg
Eu Rohs Directive:
Compliant
Tightening Torque:
< 1.4 N.m screw clamp terminals
On-Load Factor:
1
Reach Free Of Svhc:
Yes
Depth:
66 mm
Hold-In Power Consumption In Va:
5-5 VA AC
Range Compatibility:
TeSys GV2ME || TeSys GV2LE || TeSys GV2L || TeSys GV2P || TeSys GV3L || TeSys GV3P || TeSys Deca
Warranty:
18 months
Mercury Free:
Yes
Quantity Per Set:
set of 10
Color:
dark grey
Hold-In Power Consumption In W:
1.6-1.6 W
California Proposition 65:
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Toxic Heavy Metal Free:
Yes
Height:
89 mm
Width:
18 mm
[Uc] Control Circuit Voltage:
110...115 V AC 60 Hz
Range:
TeSys || TeSys Deca
Product Or Component Type:
shunt trip release
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Inrush Power In W:
10.5 W
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Operating Time:
10...15 ms IEC 60947-1
Inrush Power In Va:
14-14 VA AC
[Ui] Rated Insulation Voltage:
690 V AC IEC 60947-1 || 600 V AC UL 60947-4-1 || 600 V AC CSA C22.2 No 60947-4-1
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Datasheet:
View
$81.00

Description

TeSys GV electrical trip, MX shunt release, 110-115V AC 60Hz, for motor circuit breakers GV2, GV3. It trips the circuit breaker when the control voltage is applied in limits 0.7-1.1 Uc with an impulse duration greater than 20ms or a maintained signal. To be mounted on right-hand side of the circuit breaker, connection by screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).