Schneider Electric HDA260502 Molded Case Circuit Breaker 600V 50A

(No reviews yet) Write a Review
SKU:
HDA260502
UPC:
7.85902E+11
Condition:
New
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Magnetic Hold Current:
400 A
Suitability For Isolation:
yes IEC 60947-2
Control Type:
toggle
Warranty:
18 months
Communication Interface:
Modbus || Ethernet
Line Rated Current:
50-50 A
Product Or Component Type:
circuit breaker
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Product Name:
PowerPact H
Protected Poles Description:
2t
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Wire Stripping Length:
16 mm
Quantity Per Set:
1
Poles Description:
2P
Local Signalling:
switched off (OFF) 1 trip indicator green)
Ip Degree Of Protection:
front cover IP40 IEC 60529
Width:
104 mm
Terminal Identifier:
AL150HD
Mounting Support:
bracket
Ambient Air Temperature For Operation:
-2-70 °C
Net Weight:
2.2 kg
Trip Unit Technology:
thermal-magnetic
Sustainable Offer Status:
Green Premium product
Circuit Breaker Application:
HACR rated
Device Application:
distribution
Phase Connection:
AC
Circularity Profile:
ENVEOLI2206027EN
Quality Labels:
CE
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Pollution Degree:
3 IEC 60947-1
Mercury Free:
Yes
Continuous Current Rating:
0.8
Mounting Mode:
I-Line bracket)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Environmental Disclosure:
ENVPEP2206027EN
Rohs Exemption Information:
Yes
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Color:
Black
Pvc Free:
Yes
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Product Certifications:
UL || CSA || NOM
Mounting Height:
3 in
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
[Ics] Rated Service Breaking Capacity:
25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Range:
PowerPact
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Depth:
86 mm
Utilisation Category:
category A
Breaking Capacity Code:
D
Network Frequency:
50/60 Hz
Height:
163 mm
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Breaking Capacity:
25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
Ambient Air Temperature For Storage:
-50-85 °C
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Eu Rohs Directive:
Compliant with Exemptions
Electrical Connection:
I-Line connection, line || lugs, load
Magnetic Tripping Current:
850-850 A
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric HDA260502 Molded Case Circuit Breaker 600V 50A
  • Schneider Electric HDA260502 Molded Case Circuit Breaker 600V 50A
$899.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 50A, 2 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an AC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose