Schneider Electric HDA260804 Molded Case Circuit Breaker 600V 80A

(No reviews yet) Write a Review
SKU:
HDA260804
UPC:
785901416425
Condition:
New
Circularity Profile:
ENVEOLI2206027EN
Width:
104 mm
Breaking Capacity Code:
D
Eu Rohs Directive:
Compliant with Exemptions
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Mounting Support:
bracket
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Product Name:
PowerPact H
Phase Connection:
BC
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Pollution Degree:
3 IEC 60947-1
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Color:
Black
Breaking Capacity:
25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
Pvc Free:
Yes
Environmental Disclosure:
ENVPEP2206027EN
Warranty:
18 months
Continuous Current Rating:
0.8
Quantity Per Set:
1
Electrical Connection:
I-Line connection, line || lugs, load
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Mounting Mode:
I-Line bracket)
Product Certifications:
UL || CSA || NOM
Magnetic Hold Current:
800 A
Trip Unit Technology:
thermal-magnetic
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Wire Stripping Length:
16 mm
Device Application:
distribution
Local Signalling:
switched off (OFF) 1 trip indicator green)
Range:
PowerPact
Quality Labels:
CE
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Control Type:
toggle
Mercury Free:
Yes
Network Frequency:
50/60 Hz
Magnetic Tripping Current:
1450-1450 A
Depth:
86 mm
Sustainable Offer Status:
Green Premium product
Ip Degree Of Protection:
front cover IP40 IEC 60529
Ambient Air Temperature For Storage:
-50-85 °C
Circuit Breaker Application:
HACR rated
Net Weight:
2.2 kg
Suitability For Isolation:
yes IEC 60947-2
Line Rated Current:
80-80 A
Height:
163 mm
Communication Interface:
Modbus || Ethernet
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Utilisation Category:
category A
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Mounting Height:
3 in
Product Or Component Type:
circuit breaker
Rohs Exemption Information:
Yes
Terminal Identifier:
AL150HD
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Poles Description:
2P
Protected Poles Description:
2t
[Ics] Rated Service Breaking Capacity:
25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Ambient Air Temperature For Operation:
-2-70 °C
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Brochure:
View
Catalog:
View
Datasheet:
View
$1,632.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 80A, 2 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80% with a BC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose