Schneider Electric HDA261504 Molded Case Circuit Breaker 600V 150A

(No reviews yet) Write a Review
SKU:
HDA261504
UPC:
785901558347
Condition:
New
Ambient Air Temperature For Storage:
-50-85 °C
Product Certifications:
UL || CSA || NOM
Magnetic Hold Current:
900 A
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Width:
104 mm
Electrical Connection:
I-Line connection, line || lugs, load
Mercury Free:
Yes
Circuit Breaker Application:
HACR rated
Wire Stripping Length:
16 mm
Net Weight:
2.2 kg
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Line Rated Current:
150-150 A
Local Signalling:
switched off (OFF) 1 trip indicator green)
Ambient Air Temperature For Operation:
-2-70 °C
Terminal Identifier:
AL150HD
Eu Rohs Directive:
Compliant with Exemptions
Depth:
86 mm
Quantity Per Set:
1
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Trip Unit Technology:
thermal-magnetic
Breaking Capacity:
25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
Color:
Black
Phase Connection:
BC
Communication Interface:
Modbus || Ethernet
Pollution Degree:
3 IEC 60947-1
Device Application:
distribution
Ip Degree Of Protection:
front cover IP40 IEC 60529
Pvc Free:
Yes
Environmental Disclosure:
ENVPEP2206027EN
Suitability For Isolation:
yes IEC 60947-2
Rohs Exemption Information:
Yes
Product Name:
PowerPact H
Sustainable Offer Status:
Green Premium product
Breaking Capacity Code:
D
Magnetic Tripping Current:
1700-1700 A
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
[Ics] Rated Service Breaking Capacity:
25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Mounting Height:
3 in
Continuous Current Rating:
0.8
Mounting Mode:
I-Line bracket)
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Circularity Profile:
ENVEOLI2206027EN
Warranty:
18 months
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Protected Poles Description:
2t
Height:
163 mm
Control Type:
toggle
Product Or Component Type:
circuit breaker
Network Frequency:
50/60 Hz
Utilisation Category:
category A
Mounting Support:
bracket
Quality Labels:
CE
Poles Description:
2P
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Range:
PowerPact
Brochure:
View
Catalog:
View
Datasheet:
View
$2,195.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 150A, 2 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80% with a BC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose