Schneider Electric HDA36125SA Molded Case Circuit Breaker 600V 125A
Schneider Electric
$5,170.50
PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 125A, 3 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. This unit includes a factory installed 120VAC shunt trip. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Mounting Mode:
- I-Line bracket)
- Mounting Height:
- 4.5 in
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Pollution Degree:
- 3 IEC 60947-1
- Product Or Component Type:
- circuit breaker
- Protected Poles Description:
- 3t
- Product Name:
- PowerPact H
- Product Certifications:
- UL || CSA || NOM
- Circularity Profile:
- ENVEOLI1311006EN
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Breaking Capacity Code:
- D
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Phase Connection:
- ABC
- Sustainable Offer Status:
- Green Premium product
- Poles Description:
- 3P
- Network Frequency:
- 50/60 Hz
- Magnetic Hold Current:
- 900 A
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Accessory / Separate Part Type:
- shunt trip 110...130 V AC compartment
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Awg Gauge:
- AWG 14...AWG 3/0 aluminium/copper terminal
- Environmental Disclosure:
- ENVPEP1311006EN
- Utilisation Category:
- category A
- Net Weight:
- 2.2 kg
- Pvc Free:
- Yes
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Tightening Torque:
- 5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
- Eu Rohs Directive:
- Compliant
- Mounting Support:
- bracket
- Terminal Identifier:
- AL150HD
- Color:
- Black
- Device Application:
- distribution
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Height:
- 163 mm
- Electrical Connection:
- I-Line connection, line || lugs, load
- Quantity Per Set:
- 1
- Continuous Current Rating:
- 0.8
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
- [Ics] Rated Service Breaking Capacity:
- 25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Ambient Air Temperature For Operation:
- -2-70 °C
- Width:
- 104 mm
- Line Rated Current:
- 125-125 A
- Rohs Exemption Information:
- Yes
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Wire Stripping Length:
- 16 mm
- Quality Labels:
- CE
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-3
- Communication Interface:
- Modbus || Ethernet
- Suitability For Isolation:
- yes IEC 60947-2
- Trip Unit Technology:
- thermal-magnetic
- Range:
- PowerPact
- Warranty:
- 18 months
- Depth:
- 86 mm
- Ambient Air Temperature For Storage:
- -50-85 °C
- Control Type:
- toggle
- Mercury Free:
- Yes
- Circuit Breaker Application:
- HACR rated
- Magnetic Tripping Current:
- 1700-1700 A
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View