Schneider Electric HDL36060CU31X Molded Case Circuit Breaker 600V 60A

(No reviews yet) Write a Review
SKU:
HDL36060CU31X
UPC:
785901475545
Condition:
New
Width:
104 mm
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Mercury Free:
Yes
Warranty:
18 months
[Ics] Rated Service Breaking Capacity:
25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Eu Rohs Directive:
Compliant with Exemptions
Communication Interface:
Modbus || Ethernet
Protected Poles Description:
3t
Environmental Disclosure:
ENVPEP2206028EN
Product Or Component Type:
circuit breaker
Mounting Support:
lug
Electrical Connection:
lugs, line || lugs, load
Wire Stripping Length:
16 mm
Control Type:
toggle
Rohs Exemption Information:
Yes
Ambient Air Temperature For Operation:
-2-70 °C
Breaking Capacity:
25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
Height:
163 mm
Circuit Breaker Application:
HACR rated
Terminal Identifier:
AL150HD
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Quantity Per Set:
1
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Product Name:
PowerPact H
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Pvc Free:
Yes
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Ip Degree Of Protection:
front cover IP40 IEC 60529
Network Frequency:
50/60 Hz
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Poles Description:
3P
Pollution Degree:
3 IEC 60947-1
Trip Unit Technology:
electronic, standard, MicroLogic 3.2, LI
Product Certifications:
UL || CSA || NOM
Ambient Air Temperature For Storage:
-50-85 °C
Suitability For Isolation:
yes IEC 60947-2
Line Rated Current:
60-60 A
Breaking Capacity Code:
D
Color:
Black
Circularity Profile:
ENVEOLI2206028EN
Mounting Mode:
unit mount lug)
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Sustainable Offer Status:
Green Premium product
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Continuous Current Rating:
1
Local Signalling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
Range:
PowerPact
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Quality Labels:
CE
Device Application:
distribution
Depth:
86 mm
Net Weight:
2.2 kg
Utilisation Category:
category A
Trip Unit Name:
MicroLogic 3.2
Brochure:
View
Catalog:
View
Datasheet:
View
$1,455.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides Micrologic Standard with a 3.2 trip unit and an LI function with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT H, 60A, 3 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 100%. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.