Schneider Electric HDL36090 Molded Case Circuit Breaker 600V 90A

(No reviews yet) Write a Review
SKU:
HDL36090
UPC:
785901955917
Condition:
New
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Quality Labels:
CE
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Network Frequency:
50/60 Hz
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Product Or Component Type:
circuit breaker
Ip Degree Of Protection:
front cover IP40 IEC 60529
Mounting Support:
lug
Depth:
86 mm
Continuous Current Rating:
0.8
Net Weight:
2.2 kg
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Pvc Free:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Rohs Exemption Information:
Yes
Trip Unit Technology:
thermal-magnetic
Protected Poles Description:
3t
Environmental Disclosure:
ENVPEP2206027EN
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Pollution Degree:
3 IEC 60947-1
Device Application:
distribution
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Product Certifications:
UL || CSA || NOM
Terminal Identifier:
AL150HD
Suitability For Isolation:
yes IEC 60947-2
Quantity Per Set:
1
Poles Description:
3P
Sustainable Offer Status:
Green Premium product
Breaking Capacity:
25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
Ambient Air Temperature For Operation:
-2-70 °C
Mercury Free:
Yes
Communication Interface:
Modbus || Ethernet
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Product Name:
PowerPact H
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Circuit Breaker Application:
HACR rated
Electrical Connection:
lugs, line || lugs, load
Ambient Air Temperature For Storage:
-50-85 °C
Height:
163 mm
Line Rated Current:
90-90 A
Local Signalling:
switched off (OFF) 1 trip indicator green)
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
[Ics] Rated Service Breaking Capacity:
25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Warranty:
18 months
Width:
104 mm
Utilisation Category:
category A
Breaking Capacity Code:
D
Control Type:
toggle
Color:
Black
Magnetic Tripping Current:
1450-1450 A
Range:
PowerPact
Eu Rohs Directive:
Compliant with Exemptions
Mounting Mode:
unit mount lug)
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Circularity Profile:
ENVEOLI2206027EN
Wire Stripping Length:
16 mm
Magnetic Hold Current:
800 A
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric HDL36090 Molded Case Circuit Breaker 600V 90A
  • Schneider Electric HDL36090 Molded Case Circuit Breaker 600V 90A
  • Schneider Electric HDL36090 Molded Case Circuit Breaker 600V 90A
$1,328.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT H, 90A, 3 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose