Schneider Electric HDL36100U33X Molded Case Circuit Breaker 600V 100A

(No reviews yet) Write a Review
SKU:
HDL36100U33X
UPC:
785901497035
Condition:
New
Breaking Capacity:
25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Mounting Mode:
unit mount lug)
Protected Poles Description:
3t
Communication Interface:
Modbus || Ethernet
Suitability For Isolation:
yes IEC 60947-2
Mercury Free:
Yes
Sustainable Offer Status:
Green Premium product
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Environmental Disclosure:
ENVPEP2206028EN
Local Signalling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Quantity Per Set:
1
Breaking Capacity Code:
D
Trip Unit Technology:
electronic, standard, MicroLogic 3.2 S, LSI
Trip Unit Name:
MicroLogic 3.2 S
Circuit Breaker Application:
HACR rated
Continuous Current Rating:
0.8
Mounting Support:
lug
Poles Description:
3P
Ambient Air Temperature For Operation:
-2-70 °C
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Line Rated Current:
100-100 A
Pollution Degree:
3 IEC 60947-1
Ambient Air Temperature For Storage:
-50-85 °C
Net Weight:
2.2 kg
Color:
Black
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Circularity Profile:
ENVEOLI2206028EN
Depth:
86 mm
Quality Labels:
CE
Width:
104 mm
Range:
PowerPact
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Pvc Free:
Yes
Electrical Connection:
lugs, line || lugs, load
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Network Frequency:
50/60 Hz
Product Certifications:
UL || CSA || NOM
Device Application:
distribution
Ip Degree Of Protection:
front cover IP40 IEC 60529
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Terminal Identifier:
AL150HD
Rohs Exemption Information:
Yes
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Control Type:
toggle
Height:
163 mm
Product Or Component Type:
circuit breaker
Utilisation Category:
category A
Product Name:
PowerPact H
[Ics] Rated Service Breaking Capacity:
25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Eu Rohs Directive:
Compliant with Exemptions
Warranty:
18 months
Wire Stripping Length:
16 mm
  • Schneider Electric HDL36100U33X Molded Case Circuit Breaker 600V 100A
  • Schneider Electric HDL36100U33X Molded Case Circuit Breaker 600V 100A
  • Schneider Electric HDL36100U33X Molded Case Circuit Breaker 600V 100A
$1,673.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides Micrologic Standard with a 3.2S trip unit and an LSI function with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT H, 100A, 3 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose