Schneider Electric HDL36110 Molded Case Circuit Breaker 600V 110A

(No reviews yet) Write a Review
SKU:
HDL36110
UPC:
785901623199
Condition:
New
Breaking Capacity Code:
D
[Ics] Rated Service Breaking Capacity:
25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Pvc Free:
Yes
Circuit Breaker Application:
HACR rated
Continuous Current Rating:
0.8
Range:
PowerPact
Device Application:
distribution
Mounting Mode:
unit mount lug)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Local Signalling:
switched off (OFF) 1 trip indicator green)
Eu Rohs Directive:
Compliant with Exemptions
Communication Interface:
Modbus || Ethernet
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Quantity Per Set:
1
Environmental Disclosure:
ENVPEP2206027EN
Color:
Black
Circularity Profile:
ENVEOLI2206027EN
Ambient Air Temperature For Operation:
-2-70 °C
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Poles Description:
3P
Ip Degree Of Protection:
front cover IP40 IEC 60529
Trip Unit Technology:
thermal-magnetic
Product Name:
PowerPact H
Protected Poles Description:
3t
Magnetic Tripping Current:
1700-1700 A
Wire Stripping Length:
16 mm
Product Or Component Type:
circuit breaker
Ambient Air Temperature For Storage:
-50-85 °C
Suitability For Isolation:
yes IEC 60947-2
Electrical Connection:
lugs, line || lugs, load
Product Certifications:
UL || CSA || NOM
Utilisation Category:
category A
Rohs Exemption Information:
Yes
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Magnetic Hold Current:
900 A
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Warranty:
18 months
Control Type:
toggle
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Mounting Support:
lug
Quality Labels:
CE
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Height:
163 mm
Pollution Degree:
3 IEC 60947-1
Mercury Free:
Yes
Network Frequency:
50/60 Hz
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Breaking Capacity:
25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
Line Rated Current:
110-110 A
Net Weight:
2.2 kg
Terminal Identifier:
AL150HD
Sustainable Offer Status:
Green Premium product
Width:
104 mm
Depth:
86 mm
  • Schneider Electric HDL36110 Molded Case Circuit Breaker 600V 110A
  • Schneider Electric HDL36110 Molded Case Circuit Breaker 600V 110A
  • Schneider Electric HDL36110 Molded Case Circuit Breaker 600V 110A
$2,600.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT H, 110A, 3 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose