Schneider Electric

Schneider Electric HDL36125SA Molded Case Circuit Breaker 600V 125A

(No reviews yet) Write a Review
SKU:
HDL36125SA
UPC:
785901568483
Condition:
New
Local Signalling:
switched off (OFF) 1 trip indicator green)
Network Frequency:
50/60 Hz
Control Type:
toggle
Device Application:
distribution
Product Certifications:
UL || CSA || NOM
Pollution Degree:
3 IEC 60947-1
Poles Description:
3P
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Quality Labels:
CE
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Wire Stripping Length:
16 mm
Mounting Support:
lug
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Protected Poles Description:
3t
Utilisation Category:
category A
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Sustainable Offer Status:
Green Premium product
Rohs Exemption Information:
Yes
Suitability For Isolation:
yes IEC 60947-2
Ambient Air Temperature For Operation:
-2-70 °C
Terminal Identifier:
AL150HD
Width:
104 mm
Communication Interface:
Modbus || Ethernet
Ambient Air Temperature For Storage:
-50-85 °C
Eu Rohs Directive:
Compliant with Exemptions
Continuous Current Rating:
0.8
Net Weight:
2.2 kg
Range:
PowerPact
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
[Ics] Rated Service Breaking Capacity:
25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Breaking Capacity:
25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
Height:
163 mm
Mounting Mode:
unit mount lug)
Magnetic Hold Current:
900 A
Color:
Black
Warranty:
18 months
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Accessory / Separate Part Type:
shunt trip 110...130 V AC compartment
Depth:
86 mm
Breaking Capacity Code:
D
Quantity Per Set:
1
Trip Unit Technology:
thermal-magnetic
Product Or Component Type:
circuit breaker
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Pvc Free:
Yes
Line Rated Current:
125-125 A
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Circularity Profile:
ENVEOLI2206027EN
Electrical Connection:
lugs, line || lugs, load
Ip Degree Of Protection:
front cover IP40 IEC 60529
Magnetic Tripping Current:
1700-1700 A
Product Name:
PowerPact H
Environmental Disclosure:
ENVPEP2206027EN
Mercury Free:
Yes
Circuit Breaker Application:
HACR rated
Brochure:
View
Catalog:
View
Datasheet:
View
$3,317.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT H, 125A, 3 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80%. This unit includes a factory installed 120VAC shunt trip. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose