Schneider Electric HGA260202 Molded Case Circuit Breaker 600V 20A

(No reviews yet) Write a Review
SKU:
HGA260202
UPC:
7.85902E+11
Condition:
New
Suitability For Isolation:
yes IEC 60947-2
Protected Poles Description:
2t
Wire Stripping Length:
16 mm
Product Name:
PowerPact H
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Color:
Black
Magnetic Tripping Current:
750-750 A
Trip Unit Technology:
thermal-magnetic
Breaking Capacity Code:
G
Network Frequency:
50/60 Hz
Quantity Per Set:
1
Ambient Air Temperature For Operation:
-2-70 °C
Pvc Free:
Yes
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Width:
104 mm
Quality Labels:
CE
Mounting Mode:
I-Line bracket)
Device Application:
distribution
Circularity Profile:
ENVEOLI2206027EN
Magnetic Hold Current:
350 A
Circuit Breaker Application:
HACR rated
Phase Connection:
AC
Continuous Current Rating:
0.8
Control Type:
toggle
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Terminal Identifier:
AL150HD
Ip Degree Of Protection:
front cover IP40 IEC 60529
Communication Interface:
Modbus || Ethernet
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Mounting Height:
3 in
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Net Weight:
2.2 kg
Utilisation Category:
category A
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Range:
PowerPact
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Pollution Degree:
3 IEC 60947-1
Depth:
86 mm
Product Certifications:
UL || CSA || NOM
Ambient Air Temperature For Storage:
-50-85 °C
Warranty:
18 months
Electrical Connection:
I-Line connection, line || lugs, load
Height:
163 mm
Mounting Support:
bracket
Sustainable Offer Status:
Green Premium product
Line Rated Current:
20-20 A
Local Signalling:
switched off (OFF) 1 trip indicator green)
Environmental Disclosure:
ENVPEP2206027EN
Rohs Exemption Information:
Yes
Poles Description:
2P
Eu Rohs Directive:
Compliant with Exemptions
Product Or Component Type:
circuit breaker
Mercury Free:
Yes
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric HGA260202 Molded Case Circuit Breaker 600V 20A
  • Schneider Electric HGA260202 Molded Case Circuit Breaker 600V 20A
$1,338.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 20A, 2 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an AC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose