[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Continuous Current Rating:
0.8
Quantity Per Set:
1
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Network Frequency:
50/60 Hz
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Color:
Black
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Warranty:
18 months
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Product Name:
PowerPact H
Utilisation Category:
category A
Environmental Disclosure:
ENVPEP1311006EN
Suitability For Isolation:
yes IEC 60947-2
Device Application:
distribution
Pvc Free:
Yes
Net Weight:
2.2 kg
Height:
163 mm
Electrical Connection:
I-Line connection, line || lugs, load
Range:
PowerPact
Ambient Air Temperature For Operation:
-2-70 °C
Protected Poles Description:
2t
Phase Connection:
AC
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Pollution Degree:
3 IEC 60947-1
Ambient Air Temperature For Storage:
-50-85 °C
Width:
104 mm
Quality Labels:
CE
Eu Rohs Directive:
Compliant
Ip Degree Of Protection:
front cover IP40 IEC 60529
Circuit Breaker Application:
HACR rated
Sustainable Offer Status:
Green Premium product
Terminal Identifier:
AL150HD
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Wire Stripping Length:
16 mm
Communication Interface:
Modbus || Ethernet
Magnetic Tripping Current:
850-850 A
Rohs Exemption Information:
Yes
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Product Or Component Type:
circuit breaker
Magnetic Hold Current:
400 A
Trip Unit Technology:
thermal-magnetic
Depth:
86 mm
Line Rated Current:
40-40 A
Product Certifications:
UL || CSA || NOM
Mounting Height:
3 in
Mercury Free:
Yes
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Mounting Mode:
I-Line bracket)
Breaking Capacity Code:
G
Control Type:
toggle
Local Signalling:
switched off (OFF) 1 trip indicator green)
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Mounting Support:
bracket
Circularity Profile:
ENVEOLI1311006EN
Poles Description:
2P
$2,007.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 40A, 2 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an AC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.