Schneider Electric HGA260901 Molded Case Circuit Breaker 600V 90A
Schneider Electric
$2,338.50
PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 90A, 2 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an AB phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Rohs Exemption Information:
- Yes
- Suitability For Isolation:
- yes IEC 60947-2
- Mounting Mode:
- I-Line bracket)
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Breaking Capacity:
- 65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
- Electrical Connection:
- I-Line connection, line || lugs, load
- Product Or Component Type:
- circuit breaker
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Circularity Profile:
- ENVEOLI1311006EN
- Mercury Free:
- Yes
- Height:
- 163 mm
- Utilisation Category:
- category A
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Width:
- 104 mm
- Control Type:
- toggle
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Poles Description:
- 2P
- Tightening Torque:
- 5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
- Magnetic Hold Current:
- 800 A
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Color:
- Black
- Depth:
- 86 mm
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Eu Rohs Directive:
- Compliant
- Ambient Air Temperature For Storage:
- -50-85 °C
- Quality Labels:
- CE
- Wire Stripping Length:
- 16 mm
- Protected Poles Description:
- 2t
- Breaking Capacity Code:
- G
- Circuit Breaker Application:
- HACR rated
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Product Name:
- PowerPact H
- Communication Interface:
- Modbus || Ethernet
- Range:
- PowerPact
- Terminal Identifier:
- AL150HD
- Net Weight:
- 2.2 kg
- [Ics] Rated Service Breaking Capacity:
- 65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-3
- Quantity Per Set:
- 1
- Ambient Air Temperature For Operation:
- -2-70 °C
- Environmental Disclosure:
- ENVPEP1311006EN
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Warranty:
- 18 months
- Device Application:
- distribution
- Line Rated Current:
- 90-90 A
- Pvc Free:
- Yes
- Phase Connection:
- AB
- Mounting Height:
- 3 in
- Awg Gauge:
- AWG 14...AWG 3/0 aluminium/copper terminal
- Continuous Current Rating:
- 0.8
- Trip Unit Technology:
- thermal-magnetic
- Pollution Degree:
- 3 IEC 60947-1
- Magnetic Tripping Current:
- 1450-1450 A
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Product Certifications:
- UL || CSA || NOM
- Sustainable Offer Status:
- Green Premium product
- Network Frequency:
- 50/60 Hz
- Mounting Support:
- bracket
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View