Schneider Electric HGA36060SA Molded Case Circuit Breaker 600V 60A

(No reviews yet) Write a Review
SKU:
HGA36060SA
UPC:
785901414964
Condition:
New
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Ambient Air Temperature For Storage:
-50-85 °C
Device Application:
distribution
Circuit Breaker Application:
HACR rated
Magnetic Hold Current:
800 A
Environmental Disclosure:
ENVPEP1311006EN
Rohs Exemption Information:
Yes
Ambient Air Temperature For Operation:
-2-70 °C
Control Type:
toggle
Terminal Identifier:
AL150HD
Trip Unit Technology:
thermal-magnetic
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Local Signalling:
switched off (OFF) 1 trip indicator green)
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Sustainable Offer Status:
Green Premium product
Protected Poles Description:
3t
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Quantity Per Set:
1
Ip Degree Of Protection:
front cover IP40 IEC 60529
Wire Stripping Length:
16 mm
Quality Labels:
CE
Eu Rohs Directive:
Compliant
Product Certifications:
UL || CSA || NOM
Depth:
86 mm
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Height:
163 mm
Product Or Component Type:
circuit breaker
Width:
104 mm
Warranty:
18 months
Magnetic Tripping Current:
1450-1450 A
Poles Description:
3P
Accessory / Separate Part Type:
shunt trip 110...130 V AC compartment
Mounting Support:
bracket
Pvc Free:
Yes
Circularity Profile:
ENVEOLI1311006EN
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Network Frequency:
50/60 Hz
Utilisation Category:
category A
Mounting Height:
4.5 in
Color:
Black
Phase Connection:
ABC
Mercury Free:
Yes
Suitability For Isolation:
yes IEC 60947-2
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Line Rated Current:
60-60 A
Communication Interface:
Modbus || Ethernet
Range:
PowerPact
Pollution Degree:
3 IEC 60947-1
Net Weight:
2.2 kg
Product Name:
PowerPact H
Breaking Capacity Code:
G
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Continuous Current Rating:
0.8
Electrical Connection:
I-Line connection, line || lugs, load
Mounting Mode:
I-Line bracket)
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric HGA36060SA Molded Case Circuit Breaker 600V 60A
  • Schneider Electric HGA36060SA Molded Case Circuit Breaker 600V 60A
  • Schneider Electric HGA36060SA Molded Case Circuit Breaker 600V 60A
$3,438.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 60A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. This unit includes a factory installed 120VAC shunt trip. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose