Schneider Electric HGA36100U31X Molded Case Circuit Breaker 600V 100A

(No reviews yet) Write a Review
SKU:
HGA36100U31X
UPC:
785901559955
Condition:
New
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Product Certifications:
UL || CSA || NOM
Ambient Air Temperature For Operation:
-2-70 °C
Poles Description:
3P
Network Frequency:
50/60 Hz
Communication Interface:
Modbus || Ethernet
Pollution Degree:
3 IEC 60947-1
Mounting Support:
bracket
Electrical Connection:
I-Line connection, line || lugs, load
Environmental Disclosure:
ENVPEP2206028EN
Protected Poles Description:
3t
Wire Stripping Length:
16 mm
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Device Application:
distribution
Warranty:
18 months
Width:
104 mm
Phase Connection:
ABC
Breaking Capacity Code:
G
Quality Labels:
CE
Net Weight:
2.2 kg
Eu Rohs Directive:
Compliant with Exemptions
Rohs Exemption Information:
Yes
Mounting Mode:
I-Line bracket)
Depth:
86 mm
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Suitability For Isolation:
yes IEC 60947-2
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Utilisation Category:
category A
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Continuous Current Rating:
0.8
Ambient Air Temperature For Storage:
-50-85 °C
Line Rated Current:
100-100 A
Sustainable Offer Status:
Green Premium product
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Control Type:
toggle
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Trip Unit Technology:
electronic, standard, MicroLogic 3.2, LI
Range:
PowerPact
Trip Unit Name:
MicroLogic 3.2
Terminal Identifier:
AL150HD
Mounting Height:
4.5 in
Pvc Free:
Yes
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Ip Degree Of Protection:
front cover IP40 IEC 60529
Color:
Black
Quantity Per Set:
1
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Height:
163 mm
Circularity Profile:
ENVEOLI2206028EN
Local Signalling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Mercury Free:
Yes
Circuit Breaker Application:
HACR rated
Product Or Component Type:
circuit breaker
Product Name:
PowerPact H
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric HGA36100U31X Molded Case Circuit Breaker 600V 100A
  • Schneider Electric HGA36100U31X Molded Case Circuit Breaker 600V 100A
  • Schneider Electric HGA36100U31X Molded Case Circuit Breaker 600V 100A
$1,962.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides Micrologic Standard with a 3.2 trip unit and an LI function with a breaking capacity of 18kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 100A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.