Schneider Electric HGA36125SA Molded Case Circuit Breaker 600V 125A

(No reviews yet) Write a Review
SKU:
HGA36125SA
UPC:
7.85902E+11
Condition:
New
Sustainable Offer Status:
Green Premium product
Circuit Breaker Application:
HACR rated
Phase Connection:
ABC
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Width:
104 mm
Trip Unit Technology:
thermal-magnetic
Magnetic Tripping Current:
1700-1700 A
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Accessory / Separate Part Type:
shunt trip 110...130 V AC compartment
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Breaking Capacity Code:
G
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Product Or Component Type:
circuit breaker
Circularity Profile:
ENVEOLI2206027EN
Protected Poles Description:
3t
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Environmental Disclosure:
ENVPEP2206027EN
Communication Interface:
Modbus || Ethernet
Rohs Exemption Information:
Yes
Ambient Air Temperature For Storage:
-50-85 °C
Mounting Height:
4.5 in
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Terminal Identifier:
AL150HD
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Poles Description:
3P
Net Weight:
2.2 kg
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Product Name:
PowerPact H
Mounting Mode:
I-Line bracket)
Control Type:
toggle
Device Application:
distribution
Depth:
86 mm
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Pvc Free:
Yes
Ambient Air Temperature For Operation:
-2-70 °C
Utilisation Category:
category A
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Color:
Black
Electrical Connection:
I-Line connection, line || lugs, load
Height:
163 mm
Range:
PowerPact
Wire Stripping Length:
16 mm
Network Frequency:
50/60 Hz
Suitability For Isolation:
yes IEC 60947-2
Magnetic Hold Current:
900 A
Mounting Support:
bracket
Line Rated Current:
125-125 A
Quality Labels:
CE
Product Certifications:
UL || CSA || NOM
Warranty:
18 months
Eu Rohs Directive:
Compliant with Exemptions
Local Signalling:
switched off (OFF) 1 trip indicator green)
Quantity Per Set:
1
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Mercury Free:
Yes
Pollution Degree:
3 IEC 60947-1
Ip Degree Of Protection:
front cover IP40 IEC 60529
Continuous Current Rating:
0.8
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric HGA36125SA Molded Case Circuit Breaker 600V 125A
  • Schneider Electric HGA36125SA Molded Case Circuit Breaker 600V 125A
$4,496.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 125A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. This unit includes a factory installed 120VAC shunt trip. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose