Schneider Electric HGL36125T Molded Case Circuit Breaker 600V 125A

(No reviews yet) Write a Review
SKU:
HGL36125T
UPC:
785901566236
Condition:
New
Height:
163 mm
Pvc Free:
Yes
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Product Or Component Type:
circuit breaker
Depth:
86 mm
Terminal Identifier:
AL150HD
Utilisation Category:
category A
Magnetic Hold Current:
900 A
Magnetic Tripping Current:
1700-1700 A
Rohs Exemption Information:
Yes
Poles Description:
3P
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Electrical Connection:
lugs, line || lugs, load
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Net Weight:
2.2 kg
Wire Stripping Length:
16 mm
Environmental Disclosure:
ENVPEP2206027EN
Local Signalling:
switched off (OFF) 1 trip indicator green)
Communication Interface:
Modbus || Ethernet
Breaking Capacity Code:
G
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Width:
104 mm
Mounting Mode:
unit mount lug)
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Line Rated Current:
125-125 A
Product Name:
PowerPact H
Suitability For Isolation:
yes IEC 60947-2
Protected Poles Description:
3t
Circularity Profile:
ENVEOLI2206027EN
Warranty:
18 months
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Continuous Current Rating:
0.8
Quality Labels:
CE
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Ip Degree Of Protection:
front cover IP40 IEC 60529
Product Certifications:
UL || CSA || NOM
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Pollution Degree:
3 IEC 60947-1
Network Frequency:
50/60 Hz
Device Application:
distribution
Ambient Air Temperature For Operation:
-2-70 °C
Range:
PowerPact
Trip Unit Technology:
thermal-magnetic
Ambient Air Temperature For Storage:
-50-85 °C
Color:
Black
Eu Rohs Directive:
Compliant with Exemptions
Sustainable Offer Status:
Green Premium product
Installed Device:
trip unit field installable
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Circuit Breaker Application:
HACR rated
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Control Type:
toggle
Mercury Free:
Yes
Mounting Support:
lug
Quantity Per Set:
1
$3,599.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT H, 125A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. This unit allows field-interchangeable trip units. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.