Schneider Electric HJA260601 Molded Case Circuit Breaker 600V 60A

(No reviews yet) Write a Review
SKU:
HJA260601
UPC:
7.85902E+11
Condition:
New
Phase Connection:
AB
Continuous Current Rating:
0.8
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Product Certifications:
UL || CSA || NOM
Sustainable Offer Status:
Green Premium product
Trip Unit Technology:
thermal-magnetic
Quantity Per Set:
1
Ambient Air Temperature For Operation:
-2-70 °C
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Circuit Breaker Application:
HACR rated
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Warranty:
18 months
Wire Stripping Length:
16 mm
Magnetic Tripping Current:
1450-1450 A
Net Weight:
2.2 kg
Mercury Free:
Yes
Protected Poles Description:
2t
Color:
Black
Height:
163 mm
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Ip Degree Of Protection:
front cover IP40 IEC 60529
Depth:
86 mm
Mounting Mode:
I-Line bracket)
Pvc Free:
Yes
Terminal Identifier:
AL150HD
Pollution Degree:
3 IEC 60947-1
Suitability For Isolation:
yes IEC 60947-2
Environmental Disclosure:
ENVPEP2206027EN
Poles Description:
2P
Local Signalling:
switched off (OFF) 1 trip indicator green)
Device Application:
distribution
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Communication Interface:
Modbus || Ethernet
Magnetic Hold Current:
800 A
Utilisation Category:
category A
Line Rated Current:
60-60 A
Quality Labels:
CE
Width:
104 mm
Breaking Capacity:
100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
Rohs Exemption Information:
Yes
Mounting Support:
bracket
Circularity Profile:
ENVEOLI2206027EN
Product Or Component Type:
circuit breaker
Range:
PowerPact
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Product Name:
PowerPact H
Electrical Connection:
I-Line connection, line || lugs, load
[Ics] Rated Service Breaking Capacity:
100 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 65 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 25 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Ambient Air Temperature For Storage:
-50-85 °C
Network Frequency:
50/60 Hz
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Control Type:
toggle
Breaking Capacity Code:
J
Eu Rohs Directive:
Compliant with Exemptions
Mounting Height:
4.5 in
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric HJA260601 Molded Case Circuit Breaker 600V 60A
  • Schneider Electric HJA260601 Molded Case Circuit Breaker 600V 60A
$1,589.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 25kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 60A, 2 pole, circuit breaker has a breaking capacity of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an AB phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose