Schneider Electric HJP36100U31X Molded Case Circuit Breaker 600V 100A
Schneider Electric
$3,387.00
PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides Micrologic Standard with a 3.2 trip unit and an LI function with a breaking capacity of 25kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has terminal nuts on the line side and lugs on the load side. This PowerPacT H, 100A, 3 pole, circuit breaker has a breaking capacity of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Environmental Disclosure:
- ENVPEP1311007EN
- Awg Gauge:
- AWG 14...AWG 3/0 aluminium/copper terminal
- Communication Interface:
- Modbus || Ethernet
- Mercury Free:
- Yes
- Device Application:
- distribution
- Mounting Mode:
- unit mount lug)
- Product Name:
- PowerPact H
- Electrical Connection:
- terminal nut, line || lugs, load
- Suitability For Isolation:
- yes IEC 60947-2
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-3
- Control Type:
- toggle
- Breaking Capacity:
- 100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
- Network Frequency:
- 50/60 Hz
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Ambient Air Temperature For Storage:
- -50-85 °C
- Line Rated Current:
- 100-100 A
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Pollution Degree:
- 3 IEC 60947-1
- Ambient Air Temperature For Operation:
- -2-70 °C
- Breaking Capacity Code:
- J
- Tightening Torque:
- 5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Rohs Exemption Information:
- Yes
- Sustainable Offer Status:
- Green Premium product
- Circularity Profile:
- ENVEOLI1311007EN_V2
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Warranty:
- 18 months
- Mounting Support:
- lug
- Depth:
- 86 mm
- Width:
- 104 mm
- Product Certifications:
- UL || CSA || NOM
- Protected Poles Description:
- 3t
- Product Or Component Type:
- circuit breaker
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Quality Labels:
- CE
- Quantity Per Set:
- 1
- [Ics] Rated Service Breaking Capacity:
- 65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Range:
- PowerPact
- Circuit Breaker Application:
- HACR rated
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Eu Rohs Directive:
- Compliant
- Poles Description:
- 3P
- Color:
- Black
- Utilisation Category:
- category A
- Height:
- 163 mm
- Continuous Current Rating:
- 0.8
- Local Signalling:
- ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
- Trip Unit Technology:
- electronic, standard, MicroLogic 3.2, LI
- Terminal Identifier:
- AL150HD
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Net Weight:
- 2.2 kg
- Trip Unit Name:
- MicroLogic 3.2
- Wire Stripping Length:
- 16 mm
- Pvc Free:
- Yes
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View