Schneider Electric

Schneider Electric HLL36125SA Molded Case Circuit Breaker 600V 125A

(No reviews yet) Write a Review
SKU:
HLL36125SA
UPC:
785901825500
Condition:
New
Device Application:
distribution
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Rohs Exemption Information:
Yes
Product Name:
PowerPact H
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Continuous Current Rating:
0.8
Environmental Disclosure:
ENVPEP2206027EN
Poles Description:
3P
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Quantity Per Set:
1
Range:
PowerPact
Mounting Support:
lug
Height:
163 mm
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Protected Poles Description:
3t
Quality Labels:
CE
Trip Unit Technology:
thermal-magnetic
Breaking Capacity Code:
L
Magnetic Hold Current:
900 A
Depth:
86 mm
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Circuit Breaker Application:
HACR rated
Net Weight:
2.2 kg
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Ambient Air Temperature For Storage:
-50-85 °C
Pvc Free:
Yes
Ambient Air Temperature For Operation:
-2-70 °C
Product Certifications:
UL || CSA || NOM
Circularity Profile:
ENVEOLI2206027EN
Line Rated Current:
125-125 A
Communication Interface:
Modbus || Ethernet
Breaking Capacity:
125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
Magnetic Tripping Current:
1700-1700 A
Mercury Free:
Yes
Wire Stripping Length:
16 mm
[Ics] Rated Service Breaking Capacity:
125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Local Signalling:
switched off (OFF) 1 trip indicator green)
Warranty:
18 months
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Product Or Component Type:
circuit breaker
Utilisation Category:
category A
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Control Type:
toggle
Color:
Black
Ip Degree Of Protection:
front cover IP40 IEC 60529
Eu Rohs Directive:
Compliant with Exemptions
Width:
104 mm
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Terminal Identifier:
AL150HD
Suitability For Isolation:
yes IEC 60947-2
Network Frequency:
50/60 Hz
Electrical Connection:
lugs, line || lugs, load
Accessory / Separate Part Type:
shunt trip 110...130 V AC compartment
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Mounting Mode:
unit mount lug)
Pollution Degree:
3 IEC 60947-1
Sustainable Offer Status:
Green Premium product
Brochure:
View
Catalog:
View
Datasheet:
View
$7,466.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 50kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT H, 125A, 3 pole, circuit breaker has a breaking capacity of 50kA at 600VAC. This circuit breaker has a continuous current rating of 80%. This unit includes a factory installed 120VAC shunt trip. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.