Width:
104 mm
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Magnetic Hold Current:
1000 A
Suitability For Isolation:
yes IEC 60947-2
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Mounting Height:
4.5 in
Rohs Exemption Information:
Yes
Ambient Air Temperature For Operation:
-2-70 °C
Awg Gauge:
AWG 3/0...350 kcmil aluminium/copper terminals
Environmental Disclosure:
ENVPEP2206031EN
Quality Labels:
CE
Mounting Support:
bracket
Breaking Capacity:
25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
Pollution Degree:
3 IEC 60947-1
Continuous Current Rating:
0.8
Poles Description:
3P
Line Rated Current:
200-200 A
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Net Weight:
2.4 kg
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Tightening Torque:
25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Mounting Mode:
I-Line bracket)
Depth:
86 mm
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz IEC 60947-3
Phase Connection:
ABC
Circuit Breaker Application:
HACR rated
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Ambient Air Temperature For Storage:
-50-85 °C
Product Name:
PowerPact J
Trip Unit Technology:
thermal-magnetic
Product Certifications:
UL || CSA || NOM
Pvc Free:
Yes
Sustainable Offer Status:
Green Premium product
Wire Stripping Length:
25 mm
Product Or Component Type:
circuit breaker
Communication Interface:
Modbus || Ethernet
Magnetic Tripping Current:
2000-2000 A
Local Signalling:
switched off (OFF) 1 trip indicator green)
Height:
191 mm
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Eu Rohs Directive:
Compliant with Exemptions
Control Type:
toggle
Circularity Profile:
ENVEOLI2206031EN
Mercury Free:
Yes
Protection Type:
overload protection || short-circuit protection
Breaking Capacity Code:
D
Ip Degree Of Protection:
front cover IP40
Terminal Identifier:
AL250JD
Network Frequency:
50/60 Hz
Device Application:
distribution
Range:
PowerPact
Utilisation Category:
category A
Electrical Connection:
I-Line connection, line || lugs, load
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
[Ics] Rated Service Breaking Capacity:
25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric JDA36200 Molded Case Circuit Breaker 600V 200A
  • Schneider Electric JDA36200 Molded Case Circuit Breaker 600V 200A
  • Schneider Electric JDA36200 Molded Case Circuit Breaker 600V 200A
$2,867.00

Description

PowerPacT J-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT J-Frame circuit breakers are available with either thermal magnetic or MicroLogic electronic trip protection units. This PowerPacT J-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT J-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT J circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT J I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT J, 200A, 3 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT J circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose