Schneider Electric JDL36175SA Molded Case Circuit Breaker 600V 175A
Schneider Electric
$3,447.00
$1200 Minimum Order for Non-stock Items or $60 Addl Schneider Handling Fee Applies
PowerPacT J-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT J-Frame circuit breakers are available with either thermal magnetic or MicroLogic electronic trip protection units. This PowerPacT J-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT J-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT J circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT J, 175A, 3 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80%. This unit includes a factory installed 120VAC shunt trip. PowerPacT J circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Mounting Mode:
- unit mount lug)
- Depth:
- 86 mm
- Suitability For Isolation:
- yes IEC 60947-2
- Magnetic Tripping Current:
- 1750-1750 A
- Breaking Capacity Code:
- D
- Tightening Torque:
- 25-25 N.m 25-95 mm² (AWG 4...AWG 4/0)
- Mounting Support:
- lug
- Device Application:
- distribution
- Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
- Terminal Identifier:
- AL175JD
- Circularity Profile:
- ENVEOLI2206031EN
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- Ip Degree Of Protection:
- front cover IP40
- Product Certifications:
- UL || CSA || NOM
- Quality Labels:
- CE
- Accessory / Separate Part Type:
- shunt trip 110...130 V AC compartment
- Product Name:
- PowerPact J
- Line Rated Current:
- 175-175 A
- Magnetic Hold Current:
- 875 A
- Width:
- 104 mm
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Poles Description:
- 3P
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Communication Interface:
- Modbus || Ethernet
- Warranty:
- 18 months
- Rohs Exemption Information:
- Yes
- Mercury Free:
- Yes
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Range:
- PowerPact
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Network Frequency:
- 50/60 Hz
- Product Or Component Type:
- circuit breaker
- Ambient Air Temperature For Operation:
- -2-70 °C
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Continuous Current Rating:
- 0.8
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Pvc Free:
- Yes
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Eu Rohs Directive:
- Compliant with Exemptions
- Circuit Breaker Application:
- HACR rated
- Pollution Degree:
- 3 IEC 60947-1
- Electrical Connection:
- lugs, line || lugs, load
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Height:
- 191 mm
- Environmental Disclosure:
- ENVPEP2206031EN
- Sustainable Offer Status:
- Green Premium product
- Ambient Air Temperature For Storage:
- -50-85 °C
- Awg Gauge:
- AWG 4...AWG 4/0 aluminium/copper terminal
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Wire Stripping Length:
- 25 mm
- Net Weight:
- 2.4 kg
- Utilisation Category:
- category A
- [Ics] Rated Service Breaking Capacity:
- 25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Protection Type:
- overload protection || short-circuit protection
- Trip Unit Technology:
- thermal-magnetic
- Control Type:
- toggle
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View