- Trip Unit Technology:
- thermal-magnetic
- Width:
- 104 mm
- Phase Connection:
- ABC
- Circularity Profile:
- ENVEOLI2206031EN
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Mercury Free:
- Yes
- Ip Degree Of Protection:
- front cover IP40
- Tightening Torque:
- 25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)
- Quality Labels:
- CE
- Environmental Disclosure:
- ENVPEP2206031EN
- Product Name:
- PowerPact J
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Device Application:
- distribution
- Mounting Height:
- 4.5 in
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Electrical Connection:
- plug-in, line || plug-in, load
- Warranty:
- 18 months
- Sustainable Offer Status:
- Green Premium product
- Magnetic Tripping Current:
- 2250-2250 A
- Breaking Capacity Code:
- D
- Eu Rohs Directive:
- Compliant with Exemptions
- Utilisation Category:
- category A
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Depth:
- 86 mm
- Magnetic Hold Current:
- 1125 A
- Ambient Air Temperature For Storage:
- -50-85 °C
- Wire Stripping Length:
- 25 mm
- Awg Gauge:
- AWG 3/0...350 kcmil aluminium/copper terminals
- Continuous Current Rating:
- 0.8
- Terminal Identifier:
- AL250JD
- [Ics] Rated Service Breaking Capacity:
- 25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Suitability For Isolation:
- yes IEC 60947-2
- Ambient Air Temperature For Operation:
- -2-70 °C
- Product Certifications:
- UL || CSA || NOM
- Product Or Component Type:
- circuit breaker
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Range:
- PowerPact
- Line Rated Current:
- 225-225 A
- Pollution Degree:
- 3 IEC 60947-1
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Net Weight:
- 2.4 kg
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Circuit Breaker Application:
- HACR rated
- Communication Interface:
- Modbus || Ethernet
- Height:
- 191 mm
- Protection Type:
- overload protection || short-circuit protection
- Control Type:
- toggle
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
- Rohs Exemption Information:
- Yes
- Pvc Free:
- Yes
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Network Frequency:
- 50/60 Hz
- Mounting Mode:
- plug-in base)
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Mounting Support:
- base
- Poles Description:
- 3P