Schneider Electric JGA36200 Molded Case Circuit Breaker 600V 200A

(No reviews yet) Write a Review
SKU:
JGA36200
UPC:
785901430735
Condition:
New
Circuit Breaker Application:
HACR rated
Mounting Height:
4.5 in
Height:
191 mm
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Wire Stripping Length:
25 mm
Control Type:
toggle
Electrical Connection:
I-Line connection, line || lugs, load
Breaking Capacity Code:
G
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Pollution Degree:
3 IEC 60947-1
Ambient Air Temperature For Operation:
-2-70 °C
Net Weight:
2.4 kg
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Depth:
86 mm
Circularity Profile:
ENVEOLI2206031EN
Ambient Air Temperature For Storage:
-50-85 °C
Utilisation Category:
category A
Awg Gauge:
AWG 3/0...350 kcmil aluminium/copper terminals
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz IEC 60947-3
Mounting Mode:
I-Line bracket)
Poles Description:
3P
Ip Degree Of Protection:
front cover IP40
Warranty:
18 months
Environmental Disclosure:
ENVPEP2206031EN
Sustainable Offer Status:
Green Premium product
Suitability For Isolation:
yes IEC 60947-2
Terminal Identifier:
AL250JD
Product Name:
PowerPact J
Rohs Exemption Information:
Yes
Width:
104 mm
Range:
PowerPact
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Magnetic Tripping Current:
2000-2000 A
Protection Type:
overload protection || short-circuit protection
Magnetic Hold Current:
1000 A
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Mounting Support:
bracket
Trip Unit Technology:
thermal-magnetic
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Continuous Current Rating:
0.8
Product Certifications:
UL || CSA || NOM
Eu Rohs Directive:
Compliant with Exemptions
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Local Signalling:
switched off (OFF) 1 trip indicator green)
Network Frequency:
50/60 Hz
Pvc Free:
Yes
Device Application:
distribution
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Product Or Component Type:
circuit breaker
Mercury Free:
Yes
Communication Interface:
Modbus || Ethernet
Phase Connection:
ABC
Tightening Torque:
25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)
Line Rated Current:
200-200 A
Quality Labels:
CE
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
  • Schneider Electric JGA36200 Molded Case Circuit Breaker 600V 200A
  • Schneider Electric JGA36200 Molded Case Circuit Breaker 600V 200A
  • Schneider Electric JGA36200 Molded Case Circuit Breaker 600V 200A
$3,968.00

Description

PowerPacT J-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT J-Frame circuit breakers are available with either thermal magnetic or MicroLogic electronic trip protection units. This PowerPacT J-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. All PowerPacT J-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT J circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT J I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT J, 200A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT J circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose